Patient-specific distal radius locking plate for fixation and accurate 3D positioning in corrective osteotomy

نویسندگان

  • J. G. G. Dobbe
  • J. C. Vroemen
  • S. D. Strackee
  • G. J. Streekstra
چکیده

Preoperative three-dimensional planning methods have been described extensively. However, transferring the virtual plan to the patient is often challenging. In this report, we describe the management of a severely malunited distal radius fracture using a patient-specific plate for accurate spatial positioning and fixation. Twenty months postoperatively the patient shows almost painless reconstruction and a nearly normal range of motion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Volar Locking Plate Breakage after Nonunion of a Distal Radius Osteotomy

We report a 38-year-old male with a nonunion followed by plate breakage after volar plating of a distal radius osteotomy. Volar locking plates have added a new approach to the treatment of distal radius malunions, due to a lower morbidity of the surgical approach and the strength of the final construction, allowing early mobilization and return to function. Conclusion. Plate breakage is an unco...

متن کامل

Corrective osteotomy after damage of the distal radial physis in children: surgical technique and results.

Distal radial physis closure in children can develop severe wrist deformity (radial shortening). These patients can be treated using a single-step surgery. It was carried out in the form of a corrective osteotomy adopting the volar approach, with fixed-angle volar plate fixation and bone grafting from the iliac crest. There have been few descriptions of the use of this technique in the manageme...

متن کامل

Treatment of neglected mal:union: of the distal radius: a cases series study

 Background: Mal:::union::: is the most common complication following distal radius fractures. Aim of this study was to evaluate the results of distal radius corrective osteotomy and plate fixation by dorsal approach in the mal:::union:::. Methods: In this retrospective study, 14 patients with neglected distal radius mal:::union::: from 2005 to 2011 were studied. All patients were treated ...

متن کامل

Supracondylar Osteotomy in Valgus Knee: Angle Blade Plate Versus Locking Compression Plate

  Background: There are few studies comparing the biomechanical properties of angled blade plate and locking compression plates in supracondylar osteotomy. In the current randomized study, we prospectively compared the clinical and radiological outcomes of supracondylar osteotomy using these two plates. Methods: Forty patients with valgus knee malalignment were randomly assigned to two equal nu...

متن کامل

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...