Frequency-doubling technology perimetry for detection of the development of visual field defects in glaucoma suspect eyes: a prospective study.

نویسندگان

  • Shu Liu
  • Marco Yu
  • Robert N Weinreb
  • Gilda Lai
  • Dennis Shun-Chiu Lam
  • Christopher Kai-Shun Leung
چکیده

IMPORTANCE While standard automated perimetry (SAP) remains the reference standard for evaluation of visual field (VF) defects in glaucoma, this study demonstrates that frequency-doubling technology (FDT) perimetry is effective in monitoring visual field progression and may detect the onset of visual field defects earlier than SAP. OBJECTIVES To compare detection of the development of VF defects, rate of change of VF loss, and risk factors for progression between SAP and matrix FDT perimetry in glaucoma suspect and ocular hypertensive eyes. DESIGN, SETTING, AND PARTICIPANTS A total of 113 glaucoma suspect and ocular hypertensive eyes from 76 patients with normal SAP and FDT perimetry results at baseline were prospectively followed up for SAP and FDT perimetry testing at approximately 4-month intervals for 30 months or longer. Patients were consecutively enrolled and followed up from January 2, 2008, to February 28, 2012, at the Hong Kong Eye Hospital, Chinese University of Hong Kong. Visual field progression was defined by the development of VF defects confirmed by 3 or more consecutive examinations at a cluster of 3 or more (less conservative) or 4 or more (more conservative) locations. The rates of change of mean deviation and pattern standard deviation were evaluated with linear mixed models and the risk factors for VF progression were computed with Cox proportional hazard models. RESULTS During a median study period of 3.4 years, 8.0% of eyes developed VF defects detected by FDT perimetry, 6.2% by SAP, and 4.4% by both using the less-conservative criteria. The detection dropped to 6.2%, 4.4%, and 2.7%, respectively, when the more-conservative criteria were applied. The rate of change of pattern standard deviation was significantly faster for FDT perimetry than SAP (P < .001). Baseline average retinal nerve fiber layer thickness and the number of clock hours of abnormal retinal nerve fiber layer measurement were associated with increased risk for VF progression for both SAP and FDT perimetry. CONCLUSIONS AND RELEVANCE Frequency-doubling technology perimetry would be useful to monitor the onset of VF defects in glaucoma and may detect VF defects not evident in SAP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of matrix frequency-doubling technology perimetry and standard automated perimetry in monitoring the development of visual field defects for glaucoma suspect eyes

BACKGROUND Perimetry is indispensable for the clinical management of glaucoma suspects. Our goal is to compare the performance of standard automated perimetry (SAP) and Matrix frequency-doubling technology (FDT) perimetry in monitoring the development of visual field (VF) defects in glaucoma suspect eyes. METHODS Longitudinal data of paired SAP and FDT from 221 eyes of 155 glaucoma suspects e...

متن کامل

Short wave–automated perimetry (SWAP) versus optical coherence tomography in early detection of glaucoma

OBJECTIVE To assess the role and diagnostic effectiveness of optical coherence tomography (OCT) and short wave-automated perimetry (SWAP) to distinguish between normal, glaucoma suspects, and surely diagnosed glaucomatous eye. BACKGROUND Changes in the optic disc and retinal nerve fiber layer (RNFL) often precede the appearance of visual field defect with standard automated perimetry. Unfortu...

متن کامل

Screening for glaucoma with frequency-doubling technology and Damato campimetry.

OBJECTIVE To assess frequency-doubling technology (FDT) perimetry (Humphrey Systems, San Leandro, Calif) and Damato campimetry (Precision Vision, Villa Park, Ill) for detecting glaucoma in a public glaucoma screening. METHODS A 2-day public glaucoma screening was held at 2 different institutions. Each subject underwent 2 visual field screening tests (Damato campimetry and FDT perimetry in scr...

متن کامل

Frequency-doubling technology perimetry and multifocal visual evoked potential in glaucoma, suspected glaucoma, and control patients

INTRODUCTION The gold standard in functional glaucoma evaluation is standard automated perimetry (SAP). However, SAP depends on the reliability of the patients' responses and other external factors; therefore, other technologies have been developed for earlier detection of visual field changes in glaucoma patients. The frequency-doubling perimetry (FDT) is believed to detect glaucoma earlier th...

متن کامل

Frequency Doubling Perimetry

DOS Times Vol. 11, No. 6 December, 2005 The goal of perimetry is to establish an accurate estimate of visual field sensitivity. Perimetry is performed to detect early visual field defects, determine specific patterns of visual field loss for differential diagnosis and monitor for evidence of progression of field loss. Conventionally Standard Achromatic Perimetry (SAP) has been used to achieve t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JAMA ophthalmology

دوره 132 1  شماره 

صفحات  -

تاریخ انتشار 2014