A new exposure technique for the circumflex coronary artery system in robotic totally endoscopic coronary artery bypass grafting.

نویسندگان

  • Johannes Bonatti
  • Thomas Schachner
  • Nikolaos Bonaros
  • Günther Laufer
چکیده

We report a case of a 53-year-old female patient with isolated left main coronary artery stenosis in whom a completely endoscopic double coronary artery bypass grafting (CABG) procedure was performed. The operation was carried out on the arrested heart. A right internal mammary artery graft was sutured to the left anterior descending artery using the daVinci telemanipulation system. The left internal mammary artery was connected to the first obtuse marginal branch which was exposed with the Octopus-TE stabilizing device. This method may be useful for further development of multivessel totally endoscopic CABG procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wrist-enhanced instrumentation: moving toward totally endoscopic coronary artery bypass grafting.

BACKGROUND With the introduction of the da Vinci robotic surgical system (Intuitive Surgical, Mountain View, CA) into minimally invasive cardiac operations the outlook for performing coronary artery bypass operations "closed chest" became a reality. METHODS Between May 1999 and December 1999 this new wrist-enhanced instrumentation was used in 61 patients. Six patients suffering from single-ve...

متن کامل

High-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient

Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...

متن کامل

Facilitated endoscopic beating heart coronary artery bypass grafting using a magnetic coupling device.

BACKGROUND Suturing of a coronary anastomosis in totally endoscopic coronary artery bypass grafting on the beating heart is technically demanding. The potential benefits of the endoscopic Magnetic Vascular Positioner device (Ventrica, Inc, Fremont, Calif) to facilitate construction of a coronary anastomosis in a closed chest environment were evaluated. METHODS Totally endoscopic coronary arte...

متن کامل

History and current status of robotic totally endoscopic coronary artery bypass.

Robotic totally endoscopic coronary artery bypass (TECAB) is a minimally invasive endoscopic surgical approach using the daVinci robotic telemanipulation system to perform coronary artery bypass grafting on the arrested or beating heart. It is a procedure that can be a useful alternative to the classic open procedure performed through sternotomy. After extensive modeling in cadavers, the first ...

متن کامل

Totally endoscopic coronary artery bypass grafting is feasible in morbidly obese patients.

Development of robotic technology has enabled totally endoscopic coronary artery bypass grafting (TECAB) procedures. With complete preservation of sternal and thoracic stability, this operation would be an interesting option for obese patients, who are known to be at higher risk for deep sternal wound infection. We describe a case of successful totally endoscopic left internal mammary artery to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 5 3  شماره 

صفحات  -

تاریخ انتشار 2006