Rod monochromat sensitivity to sine wave flicker at luminances saturating the rods.

نویسندگان

  • B C Skottun
  • K Nordby
  • S Magnussen
چکیده

The flicker sensitivity (temporal modulation transfer function) of a rod monochromat was measured at luminances in the range of 8 to 782 scotopic td. The results could be fitted by a single curve shifted vertically, suggesting that rod saturation is independent of the temporal properties of the stimulus. This is consistent with the hypothesis that rod saturation is a pure receptor phenomenon.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photopic and scotopic flicker sensitivity of a rod monochromat.

The sensitivity to sine-wave flicker of a rod monochromat was compared with that of a normal subject at photopic and scotopic levels of luminance. The sensitivity of the rod monochromat in the low-frequency region (below 3 Hz at scotopic levels and below 12 to 14 Hz at photopic levels) was found to be superior to that of the control. This superiority was most pronounced at photopic levels, wher...

متن کامل

Is the rod visual field temporally homogeneous?

Cone vision has been shown to be temporally inhomogeneous across the visual field. In the periphery, contrast sensitivity is lower for low temporal frequencies and higher for high temporal frequencies. Here we ask a similar question for rod vision at mesopic luminances. Isolation is obtained by testing a well documented rod monochromat. We show that the rod visual field exhibits only a modest d...

متن کامل

Rod-cone interaction in flicker perimetry.

We have assessed the influence of the rod system on cone flicker sensitivity during flicker perimetry. For temporal frequencies above 18 Hz extrafoveal cone-mediated flicker thresholds for a white test stimulus are as much as 1.5 log units lower when measured against a large background light that saturates the rods than when measured in darkness. Following a Ganzfeld bleach extrafoveal cone fli...

متن کامل

Dark-adapted rod suppression of cone flicker detection: Evaluation of receptoral and postreceptoral interactions.

Dark-adapted rods in the area surrounding a luminance-modulated field can suppress flicker detection. However, the characteristics of the interaction between rods and each of the cone types are unclear. To address this issue, the effect that dark-adapted rods have on specific classes of receptoral and postreceptoral signals was determined by measuring the critical fusion frequencies (CFF) for r...

متن کامل

Rheological Response and Validity of Viscoelastic Model Through Propagation of Harmonic Wave in Non-Homogeneous Viscoelastic Rods

This study is concerned to check the validity and applicability of a five parameter viscoelastic model for harmonic wave propagating in the non-homogeneous viscoelastic rods of varying density. The constitutive relation for five parameter model is first developed and validity of these relations is checked. The non-homogeneous viscoelastic rods are assumed to be initially unstressed and at rest....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 19 1  شماره 

صفحات  -

تاریخ انتشار 1980