Evaluation of a personal and microenvironmental aerosol speciation sampler (PMASS).

نویسندگان

  • Alison S Geyh
  • Susanne Hering
  • Nathan Kreisberg
  • Walter John
چکیده

In this study, an all-aluminum sampler was reconfigured to a lighter weight by using plastic for structural components not contacted by aerosol. Because the sampler body was made of plastic, the aluminum size-selective cyclone inlet was redesigned into a separate, removable unit. The resulting personal and microenvironmental aerosol speciation sampler (PMASS*) is a small, compact sampler designed for assaying concentrations of each major chemical constituent of particulate matter less than or equal to 2.5 pm in aerodynamic diameter (PM2.5) as well as its mass. The sampler consists of a miniature cyclone inlet and two parallel sampling channels, each of which may accommodate a denuder, particle filter, and backup filter. One channel serves to measure mass and inorganic ions; the other, organic and elemental carbon. Six of these samplers were first evaluated in the laboratory to verify the 50% cutpoint of the redesigned cyclone inlet near the target flow rate of 4.0 L/min and to test the effect of sampler orientation, aerosol type, and flow rate on the 50% cutpoint. The six samplers were fabricated at two different times with slight modifications in construction that yielded slightly different 50% cutpoints. The units were then evaluated as microenvironmental samplers under field conditions against reference samplers in Fresno, California, and Baltimore, Maryland. Testing in Maryland also included deployment as a personal sampler. In the laboratory, the mean (+/- SD) 50% cutpoint at a 4.1 L/min flow rate was 2.52 +/- 0.08 pm. Sampler orientation did not affect performance of the cyclone. Small differences in penetration efficiency were found with different challenge aerosols. For flow rates between 3.1 and 4.9 L/min, the 50% cutpoint varied from 3.3 pm to 2.1 pm, respectively. As a microenvironmental sampler, the PMASS performed well against relevant reference samplers for elemental carbon, organic carbon, and nitrate measurements but not for mass measurements, for which the PMASS showed a significant bias of -34%. Precision estimates for PMASS elemental carbon, organic carbon, nitrate, and mass, respectively, were 6.8%, 9.0%, 11.9%, and 12.7% in Fresno and 6.6%, 8.7%, 13.6%, and 17.5% in Baltimore. For personal sampling, PMASS measurements of mass again showed a significant bias of -24% compared with the reference sampler. Precision estimates for the PMASS as a personal sampler for elemental carbon, organic carbon, nitrate, and mass were 8.1%, 19.3%, 19.1% and 24.2%, respectively. Sulfate data were not analyzable because of the large magnitude and variability of the sulfate blanks. Field testing revealed some deformation of components of the PMASS filter pack. These problems may have affected the integrity of the particle filter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laboratory evaluation of the CIP 10 personal dust sampler.

The "capteur individuel de poussiere" CIP 10 personal dust sampler--developed by the Centre d'Etudes et Recherches de Charbonnages de France (CERCHAR) research organization--is a small, quiet, lightweight unit which samples at a flow rate of 10 L/min. It is a three-stage sampler, using two stages to remove nonrespirable dust particles and one stage to collect the respirable fraction. Airflow th...

متن کامل

PM0.1 Personal Sampler for Evaluation of Personal Exposure to Aerosol Nanoparticles

A PM0.1 personal sampler devised by the authors (Furuuchi et al., 2010a) was investigated into its performance for the practical application, or on an improvement for a smaller cut-off size and also the removal of coarse particles using pre-cut impactors. The pressure drop through the inertial filter was discussed along with the separation performance since it is important to use a portable bat...

متن کامل

Performance of personal inhalable aerosol samplers in very slowly moving air when facing the aerosol source.

While personal aerosol samplers have been characterized primarily based on wind tunnel tests conducted at relatively high wind speeds, modern indoor occupational environments are usually represented by very slow moving air. Recent surveys suggest that elevated levels of occupational exposure to inhalable airborne particles are typically observed when the worker, operating in the vicinity of the...

متن کامل

A headset-mounted mini sampler for measuring exposure to welding aerosol in the breathing zone.

There is a need for a small personal aerosol sampler for measuring occupational exposure to airborne particles in the breathing zone. Existing aerosol samplers are too large to be mounted inside modern welder's protective equipment without disturbing the worker. A headset-mounted mini sampler has been developed to fill this gap with focus on manganese exposure. This mini sampler is easy to use ...

متن کامل

Field Evaluation of Personal Sampling Methods for Multiple Bioaerosols

Ambient bioaerosols are ubiquitous in the daily environment and can affect health in various ways. However, few studies have been conducted to comprehensively evaluate personal bioaerosol exposure in occupational and indoor environments because of the complex composition of bioaerosols and the lack of standardized sampling/analysis methods. We conducted a study to determine the most efficient c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Research report

دوره 122  شماره 

صفحات  -

تاریخ انتشار 2004