Exact Reconstruction From Uniformly Attenuated Helical Cone-Beam Projections in SPECT

نویسندگان

  • Qiu Huang
  • Jiangsheng You
  • Gengsheng L. Zeng
  • Grant T. Gullberg
  • E. O. Lawrence
چکیده

In recent years the development of cone-beam reconstruction algorithms has been an active research area in x-ray computed tomography (CT), and significant progress has been made in the advancement of algorithms. Theoretically exact and computationally efficient analytical algorithms can be found in the literature. However, in single photon emission computed tomography (SPECT), published cone-beam reconstruction algorithms are either approximate or involve iterative methods. The SPECT reconstruction problem is more complicated due to degradations in the imaging detection process, one of which is the effect of attenuation of gamma ray photons. Attenuation should be compensated for to obtain quantitative results. In this paper, an analytical reconstruction algorithm for uniformly attenuated cone-beam projection data is presented for SPECT imaging. The algorithm adopts the DBH method, a procedure consisting of differentiation and backprojection followed by a finite inverse cosh-weighted Hilbert transform. The significance of the proposed approach is that a selected region of interest can be reconstructed even with a detector with a reduced field of view. The algorithm is designed for a general trajectory. However, to validate the algorithm, a numerical study was performed using a helical trajectory. The implementation is efficient and the simulation result is promising.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interior SPECT- Exact and Stable ROI Reconstruction from Uniformly Attenuated Local Projections.

Single photon emission computed tomography (SPECT) is an important biomedical imaging modality. However, since gamma cameras are expensive and bulky, truncated projection data are either preferred or unavoidable. Inspired by the recent results on interior tomography in the x-ray CT field, here we present the interior SPECT approach for exact and stable reconstruction of a region of interest (RO...

متن کامل

Exact fan-beam and 4pi-acquisition cone-beam SPECT algorithms with uniform attenuation correction.

This paper presents analytical fan-beam and cone-beam reconstruction algorithms that compensate for uniform attenuation in single photon emission computed tomography. First, a fan-beam algorithm is developed by obtaining a relationship between the two-dimensional (2D) Fourier transform of parallel-beam projections and fan-beam projections. Using this relationship, 2D Fourier transforms of equiv...

متن کامل

A Reconstruction Algorithm for Helical Cone-Beam SPECT

Cone-beam SPECT provides improved sensitivity for imaging small organs like the brain and heart. However, current cone-beam tomography with the focal point traversing a planar orbit does not acquire sufficient data to give an accurate reconstruction. In this paper, we employ a data-acquisition method which obtains complete data for cone-beam SPECT by simultaneously rotating the gamma camera and...

متن کامل

An FDK-like cone-beam SPECT reconstruction algorithm for non-uniform attenuated projections acquired using a circular trajectory.

In this paper, Novikov's inversion formula of the attenuated two-dimensional (2D) Radon transform is applied to the reconstruction of attenuated fan-beam projections acquired with equal detector spacing and of attenuated cone-beam projections acquired with a flat planar detector and circular trajectory. The derivation of the fan-beam algorithm is obtained by transformation from parallel-beam co...

متن کامل

Iterative Reconstruction with Attenuation Compensation from Cone-Beam Projections Acquired via Nonpl - Nuclear Science, IEEE Transactions on

Single photon emission computed tomography (SPECT) imaging with cone-beam collimators provides improved sensitivity and spatial resolution for imaging small objects with large field-of-view detectors. It is known that Tuy’s cone-beam data sufficiency condition must be met to obtain artifact-free reconstructions. Even though Tuy’s condition was derived for an attenuation-free situation, we hypot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008