Radiation doses to patients undergoing coronary angiography and percutaneous transluminal coronary angioplasty.

نویسندگان

  • M G Delichas
  • K Psarrakos
  • E Molyvda-Athanassopoulou
  • G Giannoglou
  • K Hatziioannou
  • E Papanastassiou
چکیده

A detailed study of radiation doses received by 168 patients who underwent coronary angiography (CAG) and 102 patients who underwent percutaneous transluminal coronary angioplasty (PTCA) in two Greek hospitals is presented. Radiation dose was measured in terms of dose-area product (DAP). The contribution of fluoroscopy and cineradiography to the total DAP was examined separately for each radiological projection used in both procedures. Effective dose and doses to various organs were estimated with the help of the ODS-60 software. Total DAP was found to correlate linearly to fluoroscopy time and cine film length. Mean DAP values were found to be 80.8 +/- 28.0 Gy cm2 for CAG and 86.2 +/- 65.6 Gy cm2 for PTCAs, whereas the estimated mean values of effective dose were 20.9 +/- 7.5 and 23.2 +/- 18.1 mSv respectively. DAP to effective dose conversion coefficients were estimated to be 0.26 mSv/Gy cm2 for CAG and 0.27 mSv/Gy cm2 for PTCAs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of patients skin dose undergoing coronary angiography and Percutaneous Transluminal Coronary Angioplasty (PTCA)

Background: Practice of interventional cardiology procedures such as Coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) has largely increased in recent years and is now changing to a matter of routine in many hospitals. The purpose of this study was to measure skin and organ doses in patients undergoing CA and PTCA and to find a probable relation with c...

متن کامل

Patient dose values during interventional cardiology examinations in Yazd hospital, Iran

Background: The number of interventional cardiology (IC) procedures has increased rapidly. coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. However, it is also known that these procedures are associated with high radiation doses due to long f...

متن کامل

The value of myocardial perfusion imaging with Tc-99m MIBI for the prediction of perfusion improvement after percutaneous transluminal coronary angioplasty

  Introduction: Percutaneous transluminal coronary angioplasty (PTCA) is an effective method for revascularizing of stenotic coronary vessels. Lack of response to this treatment, either in symptomatic or asymptomatic patients, is usually due to incomplete revascularization, restenosis, and/or irreversibility of myocardial perfusion. Introduction of a noninvasive metho...

متن کامل

Operator radiation exposure during percutaneous transluminal coronary angioplasty.

Operator radiation exposure during percutaneous transluminal coronary angioplasty as compared with that during routine coronary angiography is unknown. Therefore, cumulative radiation exposure at operator eye level was measured in two physicians (operators 1 and 2) during performance of coronary angioplasty and routine coronary angiography. The physicians participated together during angioplast...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 103 2  شماره 

صفحات  -

تاریخ انتشار 2003