Plasma wakefield acceleration experiments at FACET II
نویسندگان
چکیده
During the past two decades of research, the ultra-relativistic beam-driven plasma wakefield accelerator (PWFA) concept has achieved many significant milestones. These include the demonstration of ultra-high gradient acceleration of electrons over meter-scale plasma accelerator structures, efficient acceleration of a narrow energy spread electron bunch at highgradients, positron acceleration using wakes in uniform plasmas and in hollow plasma channels, and demonstrating that highly nonlinear wakes in the ‘blow-out regime’ have the electric field structure necessary for preserving the emittance of the accelerating bunch. A new 10 GeV electron beam facility, Facilities for Accelerator Science and Experimental Test (FACET) II, is currently under construction at SLAC National Accelerator Laboratory for the next generation of PWFA research and development. The FACET II beams will enable the simultaneous demonstration of substantial energy gain of a small emittance electron bunch while demonstrating an efficient transfer of energy from the drive to the trailing bunch. In this paper we first describe the capabilities of the FACET II facility. We then describe a series of PWFA experiments supported by numerical and particle-in-cell simulations designed to demonstrate plasma wake generation where the drive beam is nearly depleted of its energy, high efficiency acceleration of the trailing bunch while doubling its energy and ultimately, quantifying the emittance growth in a single stage of a PWFA that has optimally designed matching sections. We then briefly discuss other FACET II plasma-based experiments including in situ positron generation and acceleration, and several schemes that are promising for generating sub-micron emittance bunches that will ultimately be needed for both an early application of a PWFA and for a plasma-based future linear collider.
منابع مشابه
Results from Plasma Wakefield Experiments at Facet∗
We report initial results of the Plasma Wakefield Acceleration (PWFA) Experiments performed at FACET Facility for Advanced aCcelertor Experimental Tests at SLAC National Accelerator Laboratory. At FACET a 23 GeV electron beam with 1.8 × 10 electrons is compressed to 20μm longitudinally and focused down to 10μm ×10μm transverse spot size for user driven experiments. Construction of the FACET fac...
متن کاملPlasma wakefield acceleration experiments at FACET
FACET—Facilities for Accelerator science and Experimental Test beams at SLAC—will provide high-energy-density electron and positron beams with peak currents of roughly 20 kA that will be focused down to a 10μm× 10μm transverse spot size at an energy of ∼23GeV. With FACET, the SLAC linac will support a unique program concentrating on second-generation research in plasma wakefield acceleration. T...
متن کاملLaser ionized preformed plasma
The Facility for Advanced Accelerator and Experimental Tests (FACET) at SLAC installed a 10-TW Ti : sapphire laser system for pre-ionized plasma wakefield acceleration experiments. High energy (500 mJ), short (50 fs) pulses of 800 nm laser light at 1 Hz are used at the FACET experimental area to produce a plasma column. The laser pulses are stretched to 250 fs before injection into a vapor cell...
متن کاملEvaluation of Temporal Diagnostic Techniques for Two-bunch Facet Beam
Three temporal diagnostic techniques are considered for use in the FACET facility at SLAC, which will incorporate a unique two-bunch beam for plasma wakefield acceleration experiments. The results of these experiments will depend strongly on the the inter-bunch spacing as well as the longitudinal profiles of the two bunches. A reliable, singleshot, high resolution measurement of the beam’s temp...
متن کاملPlasma Wakefield Experiments at Facet*
FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration beginning in summer 2011. The nominal FACET parameters are 23GeV, 3nC electron bunches compressed to ~20μm long and focused to ~10μm wide. The intense fields of the FACET bunches will be used to field...
متن کامل