Visual function-specific perimetry for indirect comparison of different ganglion cell populations in glaucoma.

نویسندگان

  • P A Sample
  • C F Bosworth
  • E Z Blumenthal
  • C Girkin
  • R N Weinreb
چکیده

PURPOSE To compare short-wavelength automated perimetry, frequency-doubling technology perimetry, and motion-automated perimetry, each of which assesses different aspects of visual function, in eyes with glaucomatous optic neuropathy and ocular hypertension. METHODS One hundred thirty-six eyes from 136 subjects were evaluated with all three tests as well as with standard automated perimetry. Fields were not used in the classification of study groups to prevent bias, because the major purpose of the study was to evaluate each field type relative to the others. Seventy-one of the 136 eyes had glaucomatous optic neuropathy, 37 had ocular hypertension, and 28 served as age-matched normal control eyes. Glaucomatous optic neuropathy was defined by assessment of stereophotographs. Criteria were asymmetrical cupping, the presence of rim thinning, notching, excavation, or nerve fiber layer defect. Ocular hypertensive eyes had intraocular pressure of 23 mm Hg or more on at least two occasions and normal-appearing optic disc stereophotographs. Criteria for abnormality on each visual field test were selected to approximate a specificity of 90% in the normal eyes. Thresholds for each of the four tests were compared, to determine the percentage that were abnormal within each patient group and to assess the agreement among test results for abnormality, location, and extent of visual field deficit. RESULTS Each test identified a subset of the eyes with glaucomatous optic neuropathy as abnormal: 46% with standard perimetry, 61% with short-wavelength automated perimetry, 70% with frequency-doubling perimetry, and 52% with motion-automated perimetry. In the ocular hypertensive eyes, standard perimetry was abnormal in 5%, short wavelength in 22%, frequency doubling in 46%, and motion in 30%. Fifty-four percent (38/71) of eyes with glaucomatous optic neuropathy were normal on standard fields. However, 90% were identified by at least one of the specific visual function tests. Combining tests improved sensitivity with slight reductions in specificity. The agreement in at least one quadrant, when a defect was present with more than one test, was very high at 92% to 97%. More extensive deficits were shown by frequency-doubling perimetry followed by short-wavelength automated perimetry, then motion-automated perimetry, and last, standard perimetry. However, there were significant individual differences in which test of any given pairing was more extensively affected. Only 30% (11/37) of the ocular hypertensive eyes showed no deficits at all compared with 71% (20/28) of the control eyes (P < 0.001). CONCLUSIONS For detection of functional loss standard visual field testing is not optimum; a combination of two or more tests may improve detection of functional loss in these eyes; in an individual, the same retinal location is damaged, regardless of visual function under test; glaucomatous optic neuropathy identified on stereophotographs may precede currently measurable function loss in some eyes; conversely, function loss with specific tests may precede detection of abnormality by stereophotograph review; and short-wavelength automated perimetry, frequency-doubling perimetry, and motion-automated perimetry continue to show promise as early indicators of function loss in glaucoma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neural losses correlated with visual losses in clinical perimetry.

PURPOSE The validity of clinical perimetry for evaluation of the pathology of glaucoma is based on correlated losses in retinal ganglion cells and visual sensitivity, but procedures to quantify neural losses from visual field defects have not been developed. The purpose of the present study was to investigate the neural and sensitivity losses from experimental glaucoma to establish the framewor...

متن کامل

Visual field defects and retinal ganglion cell losses in patients with glaucoma.

OBJECTIVE To determine whether the structure-function relationships for glaucoma in humans and experimental glaucoma in monkeys are similar. METHODS The study was based on retinal ganglion cell density and visual thresholds in patients with documented glaucoma. Data were analyzed with a model that predicted ganglion cell density from standard clinical perimetry, which was then compared with h...

متن کامل

Ganglion cell losses underlying visual field defects from experimental glaucoma.

PURPOSE To investigate the relationship between ganglion cell losses and visual field defects caused by glaucoma. METHODS Behavioral perimetry and histology data were obtained from 10 rhesus monkeys with unilateral experimental glaucoma that was induced by argon laser treatments to their trabecular meshwork. After significant visual field defects had developed, the retinas were collected for ...

متن کامل

Arterial spin labeling fMRI measurements of decreased blood flow in primary visual cortex correlates with decreased visual function in human glaucoma

PURPOSE Altered metabolic activity has been identified as a potential contributing factor to the neurodegeneration associated with primary open angle glaucoma (POAG). Consequently, we sought to determine whether there is a relationship between the loss of visual function in human glaucoma and resting blood perfusion within primary visual cortex (V1). METHODS Arterial spin labeling (ASL) funct...

متن کامل

Quadrant Field Pupillometry Detects Melanopsin Dysfunction in Glaucoma Suspects and Early Glaucoma

It is difficult to detect visual function deficits in patients at risk for glaucoma (glaucoma suspects) and at early disease stages with conventional ophthalmic tests such as perimetry. To this end, we introduce a novel quadrant field measure of the melanopsin retinal ganglion cell mediated pupil light response corresponding with typical glaucomatous arcuate visual field defects. The melanopsin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 41 7  شماره 

صفحات  -

تاریخ انتشار 2000