Acute and nine-month clinical outcomes after "suboptimal" coronary stenting: results from the STent Anti-thrombotic Regimen Study (STARS) registry.

نویسندگان

  • D E Cutlip
  • M B Leon
  • K K Ho
  • P C Gordon
  • A Giambartolomei
  • D J Diver
  • D M Lasorda
  • D O Williams
  • M M Fitzpatrick
  • A Desjardin
  • J J Popma
  • R E Kuntz
  • D S Baim
چکیده

OBJECTIVES This registry collected the 30-day and 9-month clinical outcomes of patients whose coronary stent implantation was suboptimal, and compared them with the cohort of patients with "optimal" stenting in the randomized portion of the STent Anti-thrombotic Regimen Study (STARS) trial. BACKGROUND Although "optimal" stenting combined with an aspirin and ticlopidine regimen carries a low (0.5%) incidence of subacute stent thrombosis, only limited data are available for patients in whom stents are deployed suboptimally. METHODS In the STARS, 312 (15.9%) of 1,965 patients enrolled were excluded from participation in the randomized trial based on a perceived "suboptimal" result of coronary stenting. Of these, 265 patients met prespecified criteria for suboptimal stenting, and were followed in a parallel registry, which was compared with the randomized STARS optimal stenting cohort. The primary end point was a 30-day composite of death, emergent target lesion revascularization, angiographic thrombosis of the target vessel without revascularization and nonfatal myocardial infarction (MI) unrelated to direct procedural complications. RESULTS Registry patients had a similar frequency of the primary end point compared with the overall randomized cohort (3.0% vs. 2.2%), with this end point correlating to use of multiple stents, smaller final lumen diameter and absence of ticlopidine from the poststent regimen. Overall 30-day mortality (1.1% vs. 0.06%, p = 0.009) and periprocedural non-Q wave MI (8.7% vs. 4.2%, p = 0.003) were more frequent in registry patients, and appeared to be related to acute procedural complications. Clinical restenosis was significantly higher for registry patients (26.8% vs. 16.0%, p = 0.001), relating to greater prevalence of independent predictors such as smaller final lumen diameter and multiple stent use. CONCLUSIONS In the STARS registry, the inability to perform optimal stenting correlated with smaller final lumen diameter and longer stent length. With ticlopidine-containing regimens, the acute clinical results of "suboptimal" stent deployment are clinically acceptable, although they are not quite as good as those of optimal stenting using similar drug therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safety and efficacy of drug-eluting balloons in percutaneous treatment of bifurcation lesions: the DEBIUT (drug-eluting balloon in bifurcation Utrecht) registry.

OBJECTIVES To evaluate outcomes after percutaneous coronary intervention (PCI) with a drug-eluting balloon catheter (paclitaxel-coated) in patients with coronary artery bifurcation lesions. BACKGROUND The current practice of provisional stenting of the main branch (MB) is reasonable; however, long-term results of side-branch (SB) treatment are suboptimal. The use of drug-eluting stents has no...

متن کامل

Safety, Efficacy and Clinical Outcome of Direct Stent Implantation

Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...

متن کامل

Late acute thrombosis after paclitaxel eluting stent implantation.

Late (more than six months) total occlusion after coronary stenting is a progressive phenomenon occurring in approximately 4% of patients, leading to acute myocardial infarction in less than 0.5%. The process must be related to severe and progressive intimal hyperplasia. In patients receiving coronary stenting with simultaneous brachytherapy, late total occlusion has been reported at a higher r...

متن کامل

Acute and Long Term Outcomes of Coronary Intervention in Unprotected Left Main Lesions

Introduction : Significant left main coronary artery stenosis jeopardizes the entire myocardium of the left ventricle and has the worst prognosis of any form of coronary artery disease. Coronary-artery bypass grafting (CABG) has been considered as the standard therapeutic approach for such patients. There are limited data on the safety and effectiveness of percutaneous coronary intervention (PC...

متن کامل

Coronary stenting in diabetic patients: Results from the ROSETTA registry.

OBJECTIVE Diabetes mellitus is associated with high rates of restenosis and adverse outcomes after percutaneous transluminal coronary angioplasty (PTCA). It is unclear whether coronary stenting reduces adverse events in diabetic patients after PTCA. Our purpose was to determine whether coronary stenting improves clinical event rates in diabetic patients after PTCA. METHODS The Routine Versus ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 34 3  شماره 

صفحات  -

تاریخ انتشار 1999