Geometric studies on variable radius spiral cone-beam scanning.
نویسندگان
چکیده
The goal is to perform geometric studies on cone-beam CT scanning along a three-dimensional (3D) spiral of variable radius. First, the background for variable radius spiral cone-beam scanning is given in the context of electron-beam CT/micro-CT. Then, necessary and sufficient conditions are proved for existence and uniqueness of PI lines inside the variable radius 3D spiral. These results are necessary steps toward exact cone-beam reconstruction from a 3D spiral scan of variable radius, adapting Katsevich's formula for the standard helical cone-beam scanning. It is shown in the paper that when the longitudinally projected planar spiral is not always convex toward the origin, the PI line may not be unique in the envelope defined by the tangents of the spiral. This situation can be avoided by using planar spirals whose curvatures are always positive. Using such a spiral, a longitudinally homogeneous region inside the corresponding 3D spiral is constructed in which any point is passed by one and only one PI line, provided the angle omega between planar spiral's tangent and radius is bounded by [omega - 90 degrees] < or = < epsilon for some positive epsilon < or = 32.48 degrees. If the radius varies monotonically, this region is larger and one may allow epsilon < or = 51.85 degrees. Examples for 3D spirals based on logarithmic and Archimedean spirals are given. The corresponding generalized Tam-Danielsson detection windows are also formulated.
منابع مشابه
Katsevich-Type Algorithms for Variable Radius Spiral Cone-Beam CT
To solve the long object problem, an exact and efficient algorithm has been recently developed by Katsevich. While the Katsevich algorithm only works with standard helical cone-beam scanning, there is an important need for nonstandard spiral cone-beam scanning. Specifically, we need a scanning spiral of variable radius for our newly proposed electron-beam CT/micro-CT prototype. In this paper, f...
متن کاملFiltered backprojection formula for exact image reconstruction from cone-beam data along a general scanning curve.
Recently, Katsevich proved a filtered backprojection formula for exact image reconstruction from cone-beam data along a helical scanning locus, which is an important breakthrough since 1991 when the spiral cone-beam scanning mode was proposed. In this paper, we prove a generalized Katsevich's formula for exact image reconstruction from cone-beam data collected along a rather flexible curve. We ...
متن کاملNumerical studies on Feldkamp-type and Katsevich-type algorithms for cone-beam scanning along nonstandard spirals
In this paper, we perform numerical studies on Feldkamp-type and Katsevich-type algorithms for cone-beam reconstruction with a nonstandard spiral locus to develop an electron-beam micro-CT scanner. Numerical results are obtained using both the approximate and exact algorithms in terms of image quality. It is observed that the two algorithms produce similar quality if the cone angle is not large...
متن کاملA half-scan error reduction based algorithm for cone-beam CT
The most popular Feldkamp algorithm for cone-beam image reconstruction assumes a scanning circle, and performs well only with a small cone angle. In this report, we propose a Feldkamp-type algorithm to increase the cone angle by several folds at a radiation dose comparable to that required by the classic Feldkamp algorithm. In our scheme, two half-scans of different radii are used. Then, approx...
متن کاملApproximate and exact cone-beam reconstruction with standard and non-standard spiral scanning.
The long object problem is practically important and theoretically challenging. To solve the long object problem, spiral cone-beam CT was first proposed in 1991, and has been extensively studied since then. As a main feature of the next generation medical CT, spiral cone-beam CT has been greatly improved over the past several years, especially in terms of exact image reconstruction methods. Now...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 31 6 شماره
صفحات -
تاریخ انتشار 2004