A target-controlled infusion system with bispectral index monitoring of propofol sedation during endoscopic submucosal dissection
نویسندگان
چکیده
BACKGROUND AND STUDY AIMS Propofol administration via a target-controlled infusion system with bispectral index monitoring (BIS/TCI system) is expected to prevent complications from sedation during complex and long endoscopic procedures. We evaluated the feasibility of setting the BIS/TCI system for non-anesthesiologist administration of propofol (NAAP) during endoscopic submucosal dissection (ESD). PATIENTS AND METHODS From May 2009 to February 2013, 250 patients with esophagogastric neoplasms were treated with ESD using the BIS/TCI system with NAAP. In the TCI system, the initial target blood concentration of propofol was set at 1.2 μg/mL. The titration speed of propofol was adjusted according to the BIS score and the movement of the patient. The BIS target level ranged from moderate to deep sedation, at which a stable BIS score between 60 and 80 was obtained. RESULTS In 80.4 % of patients, it was possible to maintain stable sedation with a blood concentration of propofol of less than 1.6 µg/mL using TCI throughout the ESD procedure. The default setting for ideal blood concentration of propofol was 1.2 μg/mL, because the medians of the lower and upper bounds of blood concentration were 1.2 μg/mL (range 0.6 - 1.8 μg/mL) and 1.4 μg/mL (range 1.0 - 3.8 μg/mL), respectively. Although hypotension occurred in 27 patients (10.8 %), oxygen desaturation occurred in only nine patients (3.6 %), and severe desaturation in only two patients (0.8 %). CONCLUSIONS Using our settings, it is possible for a non-anesthesiologist to maintain stable sedation during a lengthy endoscopic procedure through propofol sedation with a BIS/TCI system.
منابع مشابه
Bispectral Index Monitoring during Anesthesiologist-Directed Propofol and Remifentanil Sedation for Endoscopic Submucosal Dissection: A Prospective Randomized Controlled Trial
PURPOSE Endoscopic submucosal dissection (ESD) is a technically difficult and lengthy procedure requiring optimal depth of sedation. The bispectral index (BIS) monitor is a non-invasive tool that objectively evaluates the depth of sedation. The purpose of this prospective randomized controlled trial was to evaluate whether BIS guided sedation with propofol and remifentanil could reduce the numb...
متن کاملEfficacy of Bispectral Index Monitoring for Midazolam and Meperidine Induced Sedation during Endoscopic Submucosal Dissection: A Prospective, Randomized Controlled Study
BACKGROUND/AIMS Propofol induced sedation with bispectral index (BIS) monitoring has been reported to lead to higher satisfaction in patients and endoscopists during endoscopic submucosal dissection (ESD) procedures. There are no data, however, regarding the efficacy of midazolam and meperidine (M/M) induced sedation with BIS monitoring during ESD. The purpose of this study was to evaluate whet...
متن کاملOptimization of Deep Sedation with Spontaneous Respiration for Therapeutic Endoscopy Combining Propofol and Bispectral Index Monitoring
Background/Aims. This study aimed to establish optimal propofol anesthesia for therapeutic endoscopy, which has not been established. Methodology. We retrospectively investigated data on 89 patients who underwent upper-GI endoscopic submucosal dissection or endoscopic mucosal resection under anesthesia with propofol. Examined doses of propofol were changed according to efficacy and/or adverse e...
متن کاملCorrelation between Bispectral Index and Predicted Effect-site Concentration of Propofol in Different Levels of Target-Controlled, Propofol Induced Sedation in Healthy Volunteers
Introduction: Bispectral Index is an objective tool to assess electroencephalographic activity and measure the effect of certain sedatives and hypnotics on the brain. In addition, there are certain subjective tools such as the observer's assessment of alertness and sedation which are used. The correlation between BIS and the concentration of propofol in the brain, and the relationship between t...
متن کاملSafety and Efficacy of Deep Sedation with Propofol Alone or Combined with Midazolam Administrated by Nonanesthesiologist for Gastric Endoscopic Submucosal Dissection
BACKGROUND/AIMS Endoscopic submucosal dissection (ESD) is accepted as a treatment for gastric neoplasms and usually requires deep sedation. The aim of this study was to evaluate the safety and efficacy profiles of deep sedation induced by continuous propofol infusion with or without midazolam during ESD. METHODS A total of 135 patients scheduled for ESDs between December 2008 and June 2010 we...
متن کامل