Carotid intima-medial thickness measured on multiple ultrasound frames: evaluation of a DICOM-based software system
نویسندگان
چکیده
BACKGROUND Carotid intima-media thickness (CIMT) measured by B-mode ultrasonography is a marker of atherosclerosis and is commonly used as an outcome in intervention trials. We have developed DICOM-based software that measures CIMT rapidly on multiple end-diastolic image frames. The aims of this study were to compare the performance of our new software with older bitmap-based CIMT measurement software and to determine whether a ten-fold increase in the number of measurements used to calculate mean CIMT would improve reproducibility. METHODS Two independent sonographers recorded replicate carotid scans in thirty volunteers and two blinded observers measured CIMT off-line using the new DICOM-based software and older bitmap-based software. A Bland-Altman plot was used to compare CIMT results from the two software programs and t-tests were used to compare analysis times. F-tests were used to compare the co-efficients of variation (CVs) from a standard six-frame measurement protocol with CVs from a sixty-frame measurement protocol. Ordinary least products (OLP) regression was used to test for sonographer and observer biases. RESULTS The new DICOM-based software was much faster than older bitmap-based software (average measurement time for one scan 3.4 +/- 0.6 minutes versus 8.4 +/- 1.8 minutes, p < 0.0001) but CIMT measurements were larger than those made using the alternative software (+0.02 mm, 95%CI 0.01-0.03 mm). The sixty-frame measurement protocol had worse reproducibility than the six-frame protocol (inter-observer CV 5.1% vs 3.5%, p = 0.004) and inter and intra-observer biases were more pronounced in the sixty-frame than the six-frame results. CONCLUSION While the use of DICOM-based software significantly reduced analysis time, a ten-fold increase in the number of measurements used to calculate CIMT did not improve reproducibility. In addition, we found that observer biases caused differences in mean CIMT of a magnitude commonly reported as significant in intervention trials. Our results highlight the importance of good study design with concurrent controls and the need to ensure that no observer drift occurs between baseline and follow-up measurements when CIMT is used to monitor the effect of an intervention.
منابع مشابه
Evaluation of the relationship between hepatic and cardiac iron overload with MRI T2* and carotid intima media thickness with Doppler ultrasound in beta thalassemia major patients
Background: Iron overload is caused early progression of atherosclerosis in beta thalassemia patients due to regular repeated blood transfusion. MRI T2* is a gold standard non-invasive method for detecting hepatic and cardiac iron overload. The aim of this study was the comparison of carotid intima media thickness (CIMT) in the patients and healthy control groups with Doppler ultrasound for ear...
متن کاملComparison of the Intima-media Thickness of Carotid Artery in Children with Diabetes Type One and Control Group Using Ultrasound
Background & Aims: Diabetes is a very important factor for stroke due to blocked blood vessels. It can involve systemic and cerebrovascular arteries at the same time via microangiopathy and macroangiopathy. This project aimed to compare the intima-media thickness of carotid artery in children with diabetes type and the control group. Methods: In this case-control study, 50 children with the age...
متن کاملCarotid artery Intima-Media thickness and cardiovascular risk factors in chronic hemodialysis patients
Introduction: Common carotid artery intima-media thickness (CCA-IMT) correlates with cardiovascular mortality in patients under hemodialysis. In this investigation, we evaluated relationship between CCA-IMT with dependent and independent cardiovascular risk factors in chronic hemodialysis patients. Methods: In this cross-sectional study, 51 chronic hemodialysis patients, (31 males and 20 fema...
متن کاملCarotid doppler ultrasound evaluation in patients with lichen planus
Background: Lichen planus is a chronic inflammatory disease associated with an increased risk of subclinical atherosclerosis and cardiovascular diseases. This study aimed to evaluate patients with lichen planus using carotid Doppler ultrasound parameters.Methods: Forty patients with lichen planus and 40 controls were included in this study. Common carotid...
متن کاملSerum Uric Acid as a Potential Concomitant with Carotid Atherosclerosis
Background: Common carotid intima-media thickness (CC-IMT) measured by ultrasonography as a non-invasive method is nowadays known as a marker for early atherosclerosis. Objectives: Survey the relationship between serum uric acid and carotid intima-media thickness considering hypertension. Materials and Methods: This study was designed as a comparative cross-sectional study in northern Ira...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cardiovascular Ultrasound
دوره 5 شماره
صفحات -
تاریخ انتشار 2007