Grounding Grid Performance of Substation in Two Layer Soil - a Parametric Analysis

نویسندگان

  • M. G. Unde
  • B. E. Kushare
چکیده

During ground faults, fault current flows in the ground which results in potential gradient and ground potential rise (GPR). The potential gradient affects the safety of operating person due to step and touch voltage and GPR affects the insulation of protective devices and control cables. The potential gradient and GPR are the functions of ground electrode geometry. In this paper, performance assessment and analysis of grounding grid is carried out for different types of grid electrodes with two layer soil model for both positive and negative reflection factor K. The simulation is carried out to evaluate grounding grid performance indices such as Ground resistance, Mesh voltage, Step voltage, Ground Potential Rise. The various parameters used for the simulation are, depth of ground grid, Number of meshes and length of ground rods. The results are tabulated, and discussed. The SES Autogrid Pro grounding software, Canada is used for the analysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Back-flashover Investigation of HV Transmission Lines Using Transient Modeling of the Grounding Systems

The article presents the transients analysis of the substation grounding systems and transmission line tower footing resistances which can affect to the back-flashover (BF) or overvoltage across insulator chain in an HV power systems by using EMTP-RV software. The related transient modeling of the grounding systems is based on a transmission line (TL) model with considering the soil ionization....

متن کامل

Optimal Design of Grounding System for HV/ EHV Substations in Two Layered Soil

Successful operation of entire power system depends to a considerable extent on efficient and satisfactory performance of substations. Hence substations in general can be considered as heart of overall power system. In any substation, a well designed grounding plays an important role. Since absence of safe and effective grounding system can result in mal-operation or non-operation of control an...

متن کامل

Application of Electromagnetic Field Theory to Measure Correct Grounding System Impedance: A Parametric Analysis

Measurement of the grounding system impedance of a substation or power plant is often required immediately after construction, in order to verify that the design calculations correctly predict the performance of the system. Years later, new measurements are sometimes required to check that the performance of the grounding system has not deteriorated. This type of measurement, however, which is ...

متن کامل

Optimal Analysis of Grounding System Design for Distribution Substation

Abstract—This paper presents the electrical effect of two neighboring distribution substation during the construction phase. The size of auxiliary grounding grid have an effect on entire grounding system. The bigger the size of auxiliary grounding grid, the lower the GPR and maximum touch voltage, with the exception that when the two grids are unconnected, i.e. the bigger the size of auxiliary ...

متن کامل

Analysis of a Large Grounding System and Subsequent Field Test Validation Using the Fall of Potential Method

This paper examines various aspects of the design process and subsequent field test measurements of a large and complex substation grounding system. The study and measurements show that soil layering and lead interference can have a significant impact on the appropriate test location that yields the exact substation ground impedance. Applying a specific percentage rule such as the 61.8% rule fo...