Two New Parallel-plate Ionization Chambers for Electron Beam Dosimetry
نویسندگان
چکیده
-Two parallel-plate ionization chambers were projected, constructed and evauated for use in high energy electron beams. They were constructed using the two plastic materials recommended for clinical dosimetry protocols, i.e. acrylic and polystyrene. Both chambers have cylindrical shape with entrance windows in aluminized Mylar and they are open to the air. The acrylic chamber has a 2 mm air gap and the polystyrene chamber has a 1 mm air gap. Preand post-irradiation leakage, repeatability and long term stability were determined for these two ionization chambers. The ionic recombination and polarity effects, besides angular and energy dependencies, were also verified. The results obtained are within values recommended by IEC (1982) [Medical electrical equipment: dosimeters with ioniz chamber as used in radiotherapy. IEC, Geneva (IEC-731-82)] for this kind of ionization chamber. The ionization chambers were calibrated in a 20 MeV electron beam and gamma radiation of cobalt-60. The wall correction factors for the gamma radiation of cobalt-60 were 1.014 and 1.000 for the acrylic and polystyrene chambers, respectively. The ionization chambers do not present the energy dependence for the 6~20 MeV electron beam range. These results are comparable to commercially available ionization chambers.
منابع مشابه
Some steps towards establishing a tertiary standard dosimetry laboratory at a radiotherapy department
Background: In order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. When the calibration procedure is performed for a reference dosimeter in the 60Co beam of a Secondary Standard Dosimetry Laboratory (SSDL), the total uncertainty in absorbed dose to water (Dw) is estimated to be approximately 1.5%. This study attempts...
متن کاملMonte Carlo calculations of beam quality correction factors kQ for electron dosimetry with a parallel-plate Roos chamber.
Current dosimetry protocols (AAPM, IAEA, DIN) recommend the use of parallel-plate ionization chambers for the measurement of absorbed dose-to-water in clinical electron beams. For well-guarded plane-parallel chambers, it is assumed that the perturbation correction pQ is unity for all electron energies. In this study, we present detailed Monte Carlo simulations with the EGSnrc code for the widel...
متن کاملMonte Carlo calculations of beam quality correction factors
Current dosimetry protocols (AAPM, IAEA, DIN) recommend the use of parallel-plate ionization chambers for the measurement of absorbed dose-towater in clinical electron beams. For well-guarded plane-parallel chambers, it is assumed that the perturbation correction pQ is unity for all electron energies. In this study, we present detailed Monte Carlo simulations with the EGSnrc code for the widely...
متن کاملMonte Carlo calculations of correction factors for plane-parallel ionization chambers in clinical electron dosimetry.
Recent standard dosimetry protocols recommend that plane-parallel ionization chambers be used in the measurements of depth-dose distributions or the calibration of low-energy electron beams with beam quality R50 <4 g/cm2. In electron dosimetry protocols with the plane-parallel chambers, the wall correction factor, Pwall, in water is assumed to be unity and the replacement correction factor, Pre...
متن کاملThe calibration and use of plane-parallel ionization chambers for dosimetry of electron beams.
The AAPM TG 39 protocol has proposed three different methods of calibrating plane-parallel ionization chambers, i.e., in-phantom irradiation with a high-energy electron beam and in-phantom and in-air 60Co irradiation. To verify the consistency of the three methods, we have measured Ngaspp values using each of these techniques for the five most commonly used plane-parallel chambers considered by...