Thermal Considerations in Cooling Large Scale High Compute Density Data Centers
A high compute density data center of today is characterized as one consisting of thousands of racks each with multiple computing units. The computing units include multiple microprocessors, each dissipating approximately 250 W of power. The heat dissipation from a rack containing such computing units exceeds 10 KW. Today’s data center, with 1000 racks, over 30,000 square feet, requires 10 MW o...
متن کاملCfd Simulations Comparing Hard Floor and Raised Floor Configurations in an Air Cooled Data Center
An increasing number of companies and organisations have started to outsource their data storage. Although the potential of future investments in data centers is prosperous, sustainability is an increasingly important factor. It is important to make sure that the server racks in data centers are sufficiently cooled whereas too much forced cooling leads to economical losses and a waste of energy...
متن کاملAnalysis of Environmental Data in Data Centers
Optimization of data center performance for reduction in power and cooling costs is crucial to the growth of IT services both in enterprise and consumer sector. Significant work has been conducted in the past to understand the thermodynamic variables and parameters that influence the environmental conditions of the rooms vis-a-vis the computer room air conditioning (CRAC) units, racks and serve...
متن کاملEvaluation of Direct Current Distribution in Data Centers to Improve Energy Efficiency
Data centers are major power consumers. A typical new data center in the United States today has 1,000 racks, occupies 30,000 square feet, and requires 10 million watts (MW) of power to support the computing infrastructure. Projections for future data centers suggest even greater power consumption. Future 100,000-square-foot data centers could require 50 MW for the computing infrastructure and ...
متن کاملModeling and Control for Cooling Management of Data Centers with Hot Aisle Containment
In traditional raised-floor data center design with hot aisle and cold aisle separation, the cooling efficiency suffers from recirculation resulting from the mixing of cool air from the Computer Room Air Conditioning (CRAC) units and the hot exhaust air exiting from the back of the server racks. To minimize recirculation and hence increase cooling efficiency, hot aisle containment has been empl...