Design of ramped RF excitation pulses with built-in out of slab saturation for 3D - TOF angiography

نویسندگان

  • D. Kopeinigg
  • R. Bammer
چکیده

INTRODUCTION – In clinical practice, imaging of the intracranial arteries, such as the Circle of Willis (CoW), is performed most frequently with 3D TOF angiography. This noninvasive technique uses a T1-weighted RF-spoiled gradient echo (SPGR) sequence, typically in conjuction with multiple overlapping slabs (MOTSA) and RF slab excitation pulses with ramped excitation profile (TONE) to reduce blood saturation effects and to improve signal homogeneity of the vessel lumen. An additional proximal or distal SAT RF Pulse is usually added to explicitly eliminate arterial or venous blood signal, respectively. To achieve good blood saturation, the SAT band should be shifted with respect to each imaging slab and played out every TR with a corresponding gradient spoiler gradient to efficiently suppress even fast flowing blood. The addition of these additional SAT pulses, in turn, dramatically increases the scan time. Previous work by Cunningham et al. [1] showed that by concatenating a rectangle excitation profile with saturation bands on both sides can reduce scan time of triggered CE-MRA. A similar approach can be taken for TOF MRA. In this work, we leverage Shinnar-Le-Roux (SLR) transform to combine a minimum-phase small tip angle ramped excitation pulse with a onesided saturation band to either suppress the venous/or arterial signal in 3D TOF acquisitions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D Time-of-Flight MRA Using Inversion Recovery TrueFISP

A major drawback of 3D time-of-flight (TOF) sequences is progressive saturation of inflowing spins along the slab direction, and a sufficient long TR or shaped excitation pulses are required to compensate for this. Here we present a new TOF technique based on a combination of selective inversion and 3D acquisition with TrueFISP. The stationary tissue is partially suppressed by the inversion pul...

متن کامل

Implementing VERSE for Time of Flight RF pulses at 7Tesla: Methodological Considerations

INTRODUCTION. In Time-of-flight (TOF) angiography, fresh blood inflowing spins provide bright intravascular signal while static tissue signal suppression is obtained in the steady state with TR<<T1. At 1.5 and 3T, stronger background suppression is achieved with magnetization transfer (MT), and venous contribution is attenuated with saturation RF pulses. Ramp shaped RF pulses (TONE) can be used...

متن کامل

Time-Efficient Slab Selective Water Excitation

Introduction Spectral spatial (SPSP) RF pulses are simultaneously selective in both the spectral and spatial domains [1]. SPSP pulses consist of a train of slice selective RF subpulses applied simultaneously with an oscillating slice select gradient. When used for spatially selective water or fat excitation, the difference in frequency between water and fat, ∆ , limits the spacing between RF su...

متن کامل

Towards True Arterial Intracranial TOF-MRA at 7T: Protocol Optimization Using VERSE Pulses

Introduction It has been shown that the visibility of the vasculature in time-offlight (TOF) MR-angiography highly profits from increased field strengths [1-4]. To acquire truly arterial TOF data sets, the MR signal of venous blood is often saturated using spatially selective saturation pulses. Because of SAR limitations, the application of additional saturation pulses is often not possible at ...

متن کامل

Current Concepts of Cerebrovascular Disease and Stroke Magnetic Resonance Angiography Cerebrovascular Applications

Magnetic resonance angiography (MRA) can provide significant additional information to complement the routine spin-echo MR examination of the brain." The idea of a combined study has gained favor because it provides a noninvasive alternative for the complete study of patients with suspected cerebrovascular disease. Because of the relatively short time of acquisition, MRA sequences can be easify...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010