Ultra-Sensitive Anodic Stripping Voltammetry for the Determination of Xanthine at a Glassy Carbon Electrode

نویسندگان

  • Mohamed S. Ibrahim
  • Yassien M. Temerk
  • Moustafa M. Kamal
  • Hossieny S. M. Ibrahim
چکیده

An electrochemical anodic stripping procedure for ultra-trace assay of xanthine in Cu2þ solution at a glassy carbon electrode (GCE) is described. Cyclic voltammetry was used to characterize the nature of the process taking place at the GCE. The anodic stripping response in the presence of Cu2þ, at 150 mV (peak I) and 600 mV (peak II), is evaluated with respect to various experimental and instrumental conditions. Voltammetric studies show that the mechanism of the overall reaction is similar to that of the oxidation of purine derivatives at a pyrolytic graphite electrode. It is found that the copper metal deposited onto the GCE was oxidized to Cuþ at around 180 mV vs. Ag=AgCl and the generated Cuþ reacted with xanthine to accumulate on the GCE as an insoluble compound. The Cuþ-xanthine compound accumulated on the GCE was redissolved by the oxidation of Cuþ to Cu2þ at ca. 150 mV, and the concentration of xanthine in the vicinity of the GCE increased. The results enabled us to use the measurement of the oxidation peak current as the basis of a simple, accurate and rapid method of determining xanthine within a concentration range of 19.9 to 166 nM for peak (I) and 0.24 to 17.2 mM for peak (II). Promising results were obtained for xanthine determination by using an external mixing step prior to stripping measurements, which yielded a detection limit of 0.138mg L 1 (9.1 10 10 M) xanthine. The effect of some interferences (e.g. purine compounds, amino acids and some metal ions) was considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes

An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...

متن کامل

Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes

An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...

متن کامل

Study and Electrochemical Determination of Tyrosine at Graphene Nanosheets Composite Film Modified Glassy Carbon Electrode

A graphene nanosheets (GNS) film coated glassy carbon electrode (GCE) was fabricated for sensitive determination of tyrosine (Tyr). The GNS-based sensor was characterized by scanning electron microscope and electrochemical impedance spectroscopy. The voltammetric techniques were employed to study electro-oxidation of Tyr. The results revealed that the modified electrode showed an electrocatalyt...

متن کامل

Determination of Trace Mercury (Hg(II)) by Anodic Stripping Voltammetry at a Gold Electrode

ronment, the determination of trace Hg(II) is important. Atomic absorpt ion and inductively coupled plasma spectroscopic methods are currently widely used. Many publications on this subject focus on electrochemical methods (anodic and potentiometric stripping voltammetry) at a variety of electrode materials. Glassy carbon, goldplated glassy carbon, screen-printed carbon, platinum (Pt) and gold ...

متن کامل

SW Anodic Stripping Voltammetry Determination of Copper with New Tape of Modified GC Electrode

The analysis of Cu(II) by anodic stripping voltammetry using a Nafion-modified glassy Carbon electrode incorporated with Cu-DPABA complex (DPABA is Methyl 3,5bis{bis-[(pyridin-2-yl)methyl]amino}methyl)benzoate ) (Cu-DPABA–NA/GCE) is described. Cu(II) was accumulated in Hac-NaAc buffer pH=4 at potential of -0.3 V (vs. Ag/AgCl ref. electrode) and then determined with SWASV. Under the optimum cond...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004