Development of a non-extracted 'two-site' immunoradiometric assay for corticotropin utilizing extreme amino- and carboxy-terminally directed antibodies.
نویسندگان
چکیده
The development of a 'two-site' immunoradiometric assay (i.r.m.a.) for the direct estimation of human corticotropin-(1-39)-peptide in plasma is described. The assay is based on the simultaneous addition of 125I-labelled sheep anti-(N-terminal corticotropin) IgG (immunoglobulin G) antibodies and rabbit anti-(C-terminal corticotropin) antiserum to standards and unknowns (0.5 ml) followed by 18h incubation. The use of solid-phase reagents was avoided in order to minimize non-specific effects and the time required for reactants to reach equilibrium. Instead, the separation of corticotropin-bound from free labelled antibody is achieved by the addition of sheep anti-(rabbit IgG) antiserum, which precipitates bound labelled antibody by complex-formation with rabbit anti-corticotropin antibodies, which are also hormone-bound. Several 125I-labelled sheep anti-(N-terminal corticotropin) IgG preparations were assessed in the i.r.m.a. Although each was derived from antisera raised to a thyroglobulin conjugate of synthetic corticotropin-(1-24)-peptide (Synacthen), purification of immunoglobulins before iodination by selective immunoadsorption resulted in preparations with distinct specificities which demonstrated marked differences in binding to intact human corticotropin-(1-39)-peptide. These preparations are compared in combination with two rabbit anti-(C-terminal corticotropin) antisera. A 'two-site' assay based on the use of 125I-labelled sheep anti-[ corticotropin-(2-16)-peptide] IgG and rabbit anti-[corticotropin-(34-39)-peptide] antiserum was optimized, since steric inhibition of antibody binding was avoided with this combination and because the measurement of only intact human corticotropin-(1-39)-peptide and not fragments was assured by the use of terminal antibodies. This i.r.m.a. is characterized by rapid equilibration of reactants, a wide 'operating range' (the precision of dose estimates was less than 4% over the range 30-2200 pg/ml) and high sensitivity [8 pg of corticotropin/ml (95% confidence interval 3.7-12.0) (4 pg minimal detectable mass) can be detected directly in plasma].
منابع مشابه
Measurement of corticotropin in unextracted plasma: comparison of a time-resolved immunofluorometric assay and an immunoradiometric assay, with use of the same monoclonal antibodies.
We describe a time-resolved immunofluorometric assay (IFMA) for corticotropin in unextracted human plasma, based on the use of two monoclonal antibodies: europium-labeled antibody 1A12 and antibody 2A3 coated onto microtiter wells. We compared the results of this assay with those of an immunoradiometric assay (IRMA) performed with the same antibodies working ranges (CV less than 10%) were 25 to...
متن کاملImmunoradiometric assay of corticotropin with use of avidin-biotin separation.
We have developed a "sandwich"-type immunoradiometric assay for corticotropin (ACTH), with a detection limit of 2 ng/L. Two antibodies are used: a mouse monoclonal antibody directed against ACTH[1-17] and labeled with 125I; and a purified polyclonal goat antibody directed against ACTH[34-39] and conjugated to biotin. We could separate 125I-labeled antibody bound to ACTH from 125I-labeled antibo...
متن کاملImmunoradiometric assay of succinylated corticotropin: an improved method for quantification of ACTH.
In this paper we describe the development and the evaluation of a new type of immunoassay for human corticotropin (ACTH). We succeeded, by using an original approach based upon immunization with ACTH derivatized with succinic anhydride, in raising monoclonal antibodies against this poorly immunogenic peptide. Three of the antibodies were selected to develop an immunoassay for ACTH. The assay re...
متن کاملA two-site immunoradiometric assay with magnetizable particles: human liver ferritin as a model.
Using human liver ferritin as a model, we have developed a two-site immunoradiometric assay. Sample (or standard) is incubated with excess rabbit antiserum and 125I-labeled specific sheep antibodies directed against different antigenic determinants until equilibrium is reached. Then excess sheep anti-rabbit immunoglobulin G serum, covalently linked to magnetizable particles, is added. The radio...
متن کاملAmino acid differences in cat adrenocorticotropin account for the inability of a human-based immunoradiometric assay to detect the molecule in cat plasma.
A commercial immunoradiometric assay kit designed for the measurement of endogenous adrenocorticotropin (ACTH) concentrations in human plasma does not detect the molecule in plasma samples from cats. It was hypothesized that the inability of the assay to detect the molecule was related to variation(s) in the amino acid sequence of cat ACTH, compared with human ACTH. Cat ACTH complementary DNA w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Biochemical journal
دوره 218 3 شماره
صفحات -
تاریخ انتشار 1984