A doubly-fed induction generator’s (DFIG’s) sensitivity to external faults has motivated researchers to investigate the impact of various grid disturbances, such as voltage sags and short circuit faults, on its low-voltage ride-through (LVRT) capability. However, no attention has been paid to the impact of internal faults in voltage source converters (VSCs), that interface a DFIG with the grid, on the dynamic performance of the machine. This paper investigates the impacts of various VSC faults, on the dynamic performance and LVRT capability of a DFIG. Faults such as open and short circuit within VSC switches and across the DC-link capacitor are considered in this paper. The impact of internal VSC faults when they occur within the grid side converter (GSC) and rotor side converter (RSC) is investigated. Compliance of the voltage profiles of a DFIG with the LVRTs specified in the recent grid codes of the USA, Spain, Mexico, Denmark, Ireland, Germany, Quebec and the UK are examined for the faults studied. The simulation results show that these faults should be considered in designs of protection systems aimed at avoiding any catastrophic failure of the converter switches or wind turbine. 2014 Elsevier Ltd. All rights reserved.
منابع مشابه
Low Voltage Ride-Through Capability Improvement of Doubly Fed Induction Generator using DVR and SMES
Abstract: With the growth of communities and the increasing need for electricity, and because of the many benefits of renewable energy sources, the wind turbine has become a completely commercial and inevitable process, with increasing penetration into the electricity grid. Distribution networks, on the other hand, are subject to fault that cause power fluctuations and outflow of wind units. In...
متن کاملLow Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage
In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...
متن کاملUnbalanced-Grid-Fault Ride-Through Control for a Doubly Fed Induction Generator Wind Turbine with Series Grid-Side Converter
The grid codes now require doubly fed induction generator (DFIG) wind turbines having the “low voltage ride-through (LVRT)” capability. However, a traditional DFIG with a partially rated back-to-back converter has inherent difficulties to ride through the grid faults, especially for the unbalanced grid faults. Modifications to the traditional DFIG configuration for ride-through have become nece...
متن کاملDynamic Performance Of DFIG Based WECS Under Different Voltage Sag
At the present time Doubly Fed Induction Generator (DFIG) based wind energy conversion systems are widely used for large wind power plants. DFIG offers many advantages for instance reduced rating power converter, low cost and reduced losses with the better efficiency, easy in realization of power factor correction schemes, variable speed operation and four quadrants active and reactive power co...
متن کاملEfficient low-voltage ride-through nonlinear backstepping control strategy for PMSG-based wind turbine during the grid faults
This paper presents a new nonlinear backstepping controller for a direct-driven permanent magnet synchronous generator-based wind turbine, which is connected to the power system via back-to-back converters. The proposed controller deals with maximum power point tracking (MPPT) in normal condition and enhances the low-voltage ride-through (LVRT) capability in fault conditions. In this method, to...
متن کامل