Optimum conductive fabric sensor sites for evaluating the status of knee joint movements using bio-impedance
نویسندگان
چکیده
BACKGROUND There have been many studies that utilize the bio-impedance measurement method to analyze the movements of the upper and lower limbs. A fixed electrical current flows into the limbs through four standard disposable electrodes in this method. The current flows in the muscles and blood vessels, which have relatively low resistivity levels in the human body. This method is used to measure bio-impedance changes following volume changes of muscles and blood vessels around a knee joint. The result of the bio-impedance changes is used to evaluate the movements. However, the method using the standard disposable electrodes has a restriction related to its low bio-impedance changes: the standard disposable electrodes are only able to measure bio-impedance from a limited part of a muscle. Moreover, it is impossible to use continuously, as the electrodes are designed to be disposable. This paper describes a conductive fabric sensor (CFS) using a bio-impedance measurement method and determines the optimum configuration of the sensor for estimating knee joint movements. METHODS The upper side of subjects' lower limbs was divided into two areas and the lower side of subjects' lower limbs was divided into three areas. The spots were matched and 6 pairs were selected. Subjects were composed of 15 males (age: 30.7 ± 5.3, weight: 69.8 ± 4.2 kg, and height: 173.5 ± 2.8 cm) with no known problems with their knee joints. Bio-impedance changes according to knee joint flexion/extension assessments were calculated and compared with bio-impedance changes by an ankle joint flexion/extension test (SNR I) and a hip joint flexion/extension test (SNR II). RESULTS The bio-impedance changes of the knee joint flexion/extension assessment were 35.4 ± 20.0 Ω on the (1, 5) pair. SNR I was 3.8 ± 8.4 and SNR II was 6.6 ± 7.9 on the (1, 5) pair. CONCLUSIONS The optimum conductive fabric sensor configuration for evaluating knee joint movements were represented by the (1, 5) pair.
منابع مشابه
Optimum electrode configuration for detection of leg movement using bio-impedance.
Impedances and joint angles were simultaneously measured during ankle and knee movements. The correlation coefficients of the joint angle and the impedance change from human leg movement were obtained using an electro-goniometer and a four-channel impedance measurement system. Because the impedance changes resulting from ankle and knee movements depended heavily on the electrode placement, we d...
متن کاملElectrical Impedance Spectroscopy for Electro-Mechanical Characterization of Conductive Fabrics
When we use a conductive fabric as a pressure sensor, it is necessary to quantitatively understand its electromechanical property related with the applied pressure. We investigated electromechanical properties of three different conductive fabrics using the electrical impedance spectroscopy (EIS). We found that their electrical impedance spectra depend not only on the electrical properties of t...
متن کاملThe Application of Bioelectrical Impedance to Monitor Leg Movement
The purpose of this study is to provide a new approach for detection using bio-impedance. This impedance is measured by the four-electrode method. As the impedance changes resulting from ankle, knee, and hip movements depended heavily on electrode placement, we determined the optimal electrode configurations for those movements by searching for high correlation coefficients, large impedance cha...
متن کاملA new approach for detection of leg movement using segmental electrical impedance changes.
The purpose of this paper is to provide a new approach for detection using bio-impedance. This impedance is measured by the four-electrode method. As the impedance changes resulting from ankle, knee, and hip movements depend on electrode placement, we determined the optimal electrode configurations for these movements by searching for high correlation coefficients, large impedance changes, and ...
متن کاملویبروآرتروگرافی، روشی نوین در تشخیص استئوآرتریت زانو
Vibroarthrography, A Novel Technique in Diagnosis of Knee Osteoarthritis A. Rahimi PhD PT , M.M. Roostayee MSc PT , D. Shahimoridi MSc PT Received: 02/02/06 Sent for Revision: 24/06/06 Received Revised Manuscript: 27/11/06 Accepted: 26/12/06 Background and Objective: Use of joint sound signals for diagnosis of knee joint disorders has been greatly welcomed since it is a non-invasive and inexpen...