Onyx Samples Characterization by Osl Technique for High-dose Dosimetry

نویسنده

  • Caldas
چکیده

Onyx samples were studied in this work to verify their dosimetric properties. The Onyx stone is considered nobler than marble. At IPEN, the radiation metrology group has studied new materials for application in highdose dosimetry. The Onyx samples were exposed using a Gamma-Cell 220 system ( 60 Co), for doses of 50 Gy up to 300 kGy. The lower detection doses, the reproducibility of the OSL response and calibration curves were determined. All three types of Onyx samples showed good behavior for high-dose dosimetry.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of agate using the OSL technique and application in

The possibility of using Brazilian stones in gamma high-dose dosimetry was investigated at IPEN using the optically stimulated luminescence (OSL) technique. Agate samples were studied in relation to their OSL dosimetric properties, in this work. The samples were irradiated at a Gamma-Cell system (Co). The calibration curves show a sublinear behavior between 50 Gy and 300 kGy, and the lower dete...

متن کامل

OSL technique for studies of jasper samples

Jasper samples (green, red, brown, ocean and striped) were studied in relation to their optically stimulated luminescence (OSL) dosimetric properties, in this work. Since 2000, the radiation metrology group of IPEN has studied different stones as new materials for application in high-dose dosimetry. The jasper samples were exposed to different radiation doses, using the Gamma-cell 220 system (C...

متن کامل

Emergency EPR and OSL dosimetry with table vitamins and minerals.

Several table vitamins, minerals and L-lysine amino acid have been preliminarily tested as potential emergency dosemeters using electron paramagnetic resonance (EPR) and optically stimulated luminescence (OSL) techniques. Radiation-induced EPR signals were detected in samples of vitamin B2 and L-lysine while samples of multivitamins of different brands as well as mineral Mg demonstrated promine...

متن کامل

Optically stimulated luminescence (OSL) of carbon-doped aluminum oxide (Al2O3:C) for film dosimetry in radiotherapy.

INTRODUCTION AND PURPOSE Conventional x-ray films and radiochromic films have inherent challenges for high precision radiotherapy dosimetry. Here we have investigated basic characteristics of optically stimulated luminescence (OSL) of irradiated films containing carbon-doped aluminum oxide (Al2O3:C) for dosimetry in therapeutic photon and electron beams. MATERIALS AND METHODS The OSL films co...

متن کامل

Development of Osl Reader Systems for Radiation Dosimetry

Thermoluminescence (TL) and optically stimulated luminescence (OSL) techniques are known as a research tools for the study of phosphor materials and for their applications in radiation dosimetry in particular [1]. Although TL technique is known since several decades, OSL is relatively newer technique. The TL or OSL emission from an irradiated sample arises upon stimulation with heat or light re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015