On-line liquid chromatography and circular dichroism detection of stereo-isomers of alpha-tocopherol derivatives generated by an electrochemical reaction.
نویسندگان
چکیده
The electrochemical oxidation of (+/-)-alpha-tocopherol on a porous graphite electrode was performed in the presence of methanol, and successive separation and detection of the products were performed by an on-line liquid chromatography/mass spectrometry system. Three products were identified, one of which was determined to be alpha-tocopheryl quinone, because its m/z was 469 [M+Na](+). The other two products showed identical mass and UV spectra, and were suspected to be diastereomers of 9-methoxy-alpha-tocopheron, because their molecular weights were m/z 483 [M+Na](+), and also because it is known that the chemical oxidation of alpha-tocopherol by benzoyl peroxide or N-bromosuccinimide in the presence of methanol should provide 9-methoxy-alpha-tocopheron. To confirm that these two compounds were diastereomers, a circular dichroism detector was used. The signs of both peaks detected by the circular dichroism detector at 230 nm were opposite. In addition to observations of identical mass and ultraviolet spectra, these results indicated that the two products were diastereomers of 9-methoxy-alpha-tocopheron, whose stereochemistry is different at the newly generated chiral center of the 9-position. The on-line use of a circular dichroism detector with an electrochemical cell/liquid chromatography system may expand the utility of the system to study the metabolism of a chiral drug.
منابع مشابه
Determination of retinol, alpha-tocopherol, and beta-carotene in serum by liquid chromatography with absorbance and electrochemical detection.
We describe a method for the determination of retinol, alpha-tocopherol, and beta-carotene in serum, using a liquid-chromatographic separation with wavelength-programmed ultraviolet/visible absorbance and amperometric electrochemical detection with a glassy carbon electrode. After protein denaturation and addition of an internal standard, tocol, 250-microL samples are twice extracted with hexan...
متن کاملDetermination of vitamin E in microsamples of serum by liquid chromatography with electrochemical detection.
In this procedure for determination of vitamin E by "high-performance" liquid chromatography with electrochemical detection, 25-microL serum specimens are deproteinized with ethanol. Vitamin E (alpha-tocopherol), its derivatives (beta- and gamma-tocopherols), and the internal standard (delta-tocopherol) are extracted into heptane and the extract is evaporated and the residue reconstituted with ...
متن کاملSimultaneous determination of homologues of vitamin E and coenzyme Q and products of alpha-tocopherol oxidation.
A sensitive procedure is described for the simultaneous determination of vitamin E and coenzyme Q homologues and alpha-tocopherol oxidation products using two-isocratic step high pressure liquid chromatography (HPLC) and electrochemical detection in the oxidative mode. Zinc-catalyzed reduction in a post-column reactor allows the detection of alpha-tocopherolquinone, epoxy-tocopherolquinone, and...
متن کامل[Application of difference circular dichroism (CD) spectroscopy for determination of pharmaceutical compounds. Analysis of stereoisomers by the HPLC-CD/UV method].
Circular dichroism (CD) spectroscopy is gaining an increasing importance in pharmaceutical analysis. One of the main advantages of the CD spectroscopic method is its inherent selectivity, which provides the selective analysis of chiral molecules possessing optically active absorbance bands. In addition to direct CD spectroscopic methods, several new procedures have been developed based on CD sp...
متن کاملApplied Circular Dichroism: A Facile Spectroscopic Tool for Configurational Assignment and Determination of Enantiopurity
In order to determine if electronic circular dichroism (ECD) is a good tool for the qualitative evaluation of absolute configuration and enantiopurity in the absence of chiral high performance liquid chromatography (HPLC), ECD studies were performed on several prescriptions and over-the-counter drugs. Cotton effects (CE) were observed for both S and R isomers between 200 and 300 nm. For the dru...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 24 7 شماره
صفحات -
تاریخ انتشار 2008