A Rare Case of Intra-Articular Displacement of EndoButton Following Anterior Cruciate Ligament Reconstruction

نویسندگان

  • Sean WL Ho
  • Keng Thiam Lee
چکیده

The EndoButton is a commonly used device for femoral fixation of anterior cruciate ligament grafts. Complications from its usage remain rare. Incorrect femoral tunnel placement may increase the risk of intra-articular displacement of the EndoButton. We present a case of anterior femoral tunnel placement resulting in intra-articular displacement of the EndoButton after failure. A 24-year-old man presented to us after failure of anterior cruciate ligament reconstruction performed 3 years prior. Radiographs revealed an intra-articular displacement of the EndoButton. Intraoperatively, it was noted that the femoral tunnel exit was within the suprapatellar pouch, with the displaced EndoButton lodged between the posterior aspect of the lateral tibial plateau and the capsule. Intra-articular displacement of the EndoButton is a rare complication and has only been reported twice in the literature. Anterior placement of the femoral tunnel may predispose patients to this complication and it is recommended to check the EndoButton position intraoperatively to avoid such a complication, especially for the unexperienced surgeon.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does Intravenous or Intraarticular Tranexamic Acid (TXA) Reduce Joint Bleeding Following Arthroscopic Anterior Cruciate Ligament (ACL) Reconstruction and Arthroscopic Meniscectomy? Can Intraarticular Use be Harmful to Chondrocytes?

Arthroscopic knee surgery to perform partial meniscectomy and anterior cruciate ligament (ACL) reconstruction is frequent and effective, although a possible complication is postoperative intra-articular bleeding. When this complication occurs, in addition to the associated pain, the patient usually requires an arthrocentesis to avoid loss of joint mobility. Sometimes this problem ends up associ...

متن کامل

The Effect of Gentamycin in the Irrigating Solution to Prevent Joint Infection after Anterior Cruciate Ligament (ACL) Reconstruction

Background: Arthroscopic reconstruction of ACL is an effective method to restore knee stability after ACL rupture.Postoperative septic arthritis (SA) is very uncommon while the incidence of serious complications range between0.14% and 1.8%. Some of the devastating consequences of septic arthritis can encompass hyaline cartilage damage,arthrofibrosis, and in rare cases amputation. The purpose of...

متن کامل

Femoral Condyle Fracture during Revision of Anterior Cruciate Ligament Reconstruction: Case Report and a Review of Literature

 Background: A rare and devastating complication following anterior cruciate ligament (ACL) revision reconstruction is femoral fracture.    Case presentation: A 35-year old male soccer player with a history of ACL tear from the previous year ago, who underwent arthroscopic ACL reconstruction and functioned well until another similar injury caused ACL re-rupture. Revision of ACL reconstruction w...

متن کامل

Femoral Condyle Fracture during Anterior Cruciate Ligament Reconstruction

Dear Editor,We have greatly enjoyed reading the case report entitled “‘Femoral Condyle Fracture during Revision of Anterior Cruciate Ligament Reconstruction: Case Report and a Review of Literature in the issue of Arch Bone Jt Surg. 2015;3(2) with great interest. We would like to commend the authors for their detailed and valuable work. Although various case reports have described postoperative ...

متن کامل

Displacement of a Fixed Versus Adjustable Suspensory Fixation Device for Anterior Cruciate Ligament Reconstruction

Suspensory fi xation devices in anatomic anterior cruciate ligament (ACL) reconstruction commonly feature a button that rests on the cortex of the femur, and a loop that holds the graft in position until healing can occur. While this loop can be closed and fi xed in length, some contemporary designs feature a loop that is adjustable. The purpose of this study was to assess the displacement of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017