Evaluation of a hand carried cardiac ultrasound device in an outpatient cardiology clinic.
نویسندگان
چکیده
OBJECTIVE To determine the diagnostic potential of a hand carried cardiac ultrasound (HCU) device (OptiGo, Philips Medical Systems) in a cardiology outpatient clinic and to compare the HCU diagnosis with the clinical diagnosis and diagnosis with a full featured standard echocardiography (SE) system. METHODS 300 consecutive patients took part in the study. The HCU examination was performed by an experienced echocardiographer before patients visited the cardiologist. The echocardiographer noted whether the HCU device was able to confirm or reject the referral diagnosis, which abnormality was detected, and whether SE investigation was necessary. Physical examination by a cardiologist followed and thereafter, whenever required, a complete study with an SE was carried out. The HCU data were compared with the clinical diagnosis of the cardiologist and the SE diagnosis in a blinded manner. RESULTS The cardiologist referred 203 of 300 patients for an SE study and 13 patients for transoesophageal echocardiography. In 84 patients no further examination was considered necessary. HCU echocardiography was able to confirm or reject the suspected clinical diagnosis in 159 of 203 (78%) patients. In 44 of 203 (22%) patients SE Doppler was needed. Agreement between the HCU device and the SE system for the detection of major abnormalities was excellent (98%). The HCU device missed 4% of the major findings. Among the 84 patients not referred for an SE, the HCU device detected unsuspected major abnormalities missed with the physical examination in 14 (17%). CONCLUSION Integration of an HCU device with the physical examination augments the yield of information.
منابع مشابه
CARDIOVASCULAR MEDICINE Evaluation of a hand carried cardiac ultrasound device in an outpatient cardiology clinic
Objective: To determine the diagnostic potential of a hand carried cardiac ultrasound (HCU) device (OptiGo, Philips Medical Systems) in a cardiology outpatient clinic and to compare the HCU diagnosis with the clinical diagnosis and diagnosis with a full featured standard echocardiography (SE) system. Methods: 300 consecutive patients took part in the study. The HCU examination was performed by ...
متن کاملMultimodality imaging of right ventricular perforation secondary to pacing lead migration.
of pocket-size imaging devices: a position statement of the European Association of Echocardiography. Eur J Echocardiogr 2011;12:85–7. 11. Kobal SL, Trento L, Baharami S, Tolstrup K, Naqvi TZ, Cercek B et al. Comparison of effectiveness of hand-carried ultrasound to bedside cardiovascular physical examination. Am J Cardiol 2005;96:1002–6. 12. Razi R, Estrada JR, Doll J, Spencer KT. Bedside hand...
متن کاملHand-carried ultrasound performed at bedside in cardiology inpatient setting – a comparative study with comprehensive echocardiography
BACKGROUND Hand-carried ultrasound (HCU) devices have been demonstrated to improve the diagnosis of cardiac diseases over physical examination, and have the potential to broaden the versatility in ultrasound application. The role of these devices in the assessment of hospitalized patients is not completely established. In this study we sought to perform a direct comparison between bedside evalu...
متن کاملImpact of hand-carried cardiac ultrasound on diagnosis and management during cardiac consultation rounds.
AIM To evaluate the impact of hand-carried cardiac ultrasound (HCU) on the diagnosis and management of patients during cardiac consultation rounds. METHODS AND RESULTS One hundred and fifty patients hospitalized in non-cardiac units were included after the consulting cardiologist felt that an echocardiographic examination was indicated as part of his work-up. They were randomly allocated to e...
متن کاملImplantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Heart
دوره 91 2 شماره
صفحات -
تاریخ انتشار 2005