Evaluation of the Radiometer ‘ABL4’ pH/blood gas/K+/Hb analyser

نویسندگان

  • Bénédicte Beneteau-Burnat
  • Michel Vaubourdolle
  • Messereth Kebede
  • Richard Kowalezyk
  • Jacqueline Giboudeau
چکیده

The ABL4 analyser is designed for stat determination of blood gas (pCO2, pO2), pH, potassium and haemoglobin (Hb), a panel particularly adapted to the follow-up of liver transplantation. The performance of the analyser in classical tests was evaluated; in addition, K+ measurements were performed in specific conditions (linearity in a non-physiological range, erythrocyte interference). The evaluation of precision and comparison of methods were carried out according to the guidelines of the SFBC (Soci6t6 Franqaise de Biologic Clinique), which are similar to those of the NCCLS (EP5-P and EP9-P). Within-run and between-run precision and percentage CV were within the allowable limits of error (see table 1).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of the i-STAT bedside blood gas analyser.

The performance of the i-STAT portable clinical analyser for measuring blood gases and pH was evaluated with reference to a conventional blood gas analyser (ABL520 Radiometer). Ninety-two samples from the routine blood gas analysis laboratory were chosen according to a wide distribution of partial pressure of carbon dioxide (Pa,CO2), partial pressure oxygen (Pa,O2) and pH and then analysed. All...

متن کامل

SCIENTIFIC PRESENTATION AWARD Clinical Accuracy of Continuous Hemoglobin Oxygen Saturation Monitoring Devices

-----------------Three devices used to measure hemoglobin oxygen saturation in the extracorporeal circuit were studied and compared to a control. The Baxter Bentley OxySat, Oximetrix Accusat, and the Radiometer ABL4 blood gas monitor were compared to a control, the IL 282 CoOximeter. Fifty one sample points were obtained during all phases of cardiopulmonary bypass with results as follows: TABLE...

متن کامل

Clinical accuracy of continuous hemoglobin oxygen saturation monitoring devices.

Three devices used to measure hemoglobin oxygen saturation in the extracorporeal circuit were studied and compared to a control. The Baxter Bentley OxySat, Oximetrix Accusat, and Radiometer ABL4 blood gas monitor were compared to a control, the IL 282 Co-Oximeter. Fifty-one sample points were obtained during all phases of cardiopulmonary bypass with results as follows: table: see text. The Ac...

متن کامل

Implementation of the ABL-90 blood gas analyzer in a ground-based mobile emergency care unit

Point-of Care analysis is increasingly being applied in the prehospital scene. Arterial blood gas analysis is one of many new initiatives adding to the diagnostic tools of the prehospital physician. In this paper we present a study on the feasibility of the Radiometer ABL-90 in a ground-based Mobile Emergency Care Unit and report on some clinical situations in which the apparatus has proven ben...

متن کامل

Assessing the ABL 500 blood gas analyser

The ABL 500 blood gas analyser from Radiometer has cordless electrodes and does not use a humidifier for calibrating gases. During the evaluation of the analytical performance of this instrument, the problem of p0(2) accuracy was approached by comparing the values obtained with two kinds of tonometry (film and bubble). An acceptable level of imprecision was demonstrated for all measured paramet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 11  شماره 

صفحات  -

تاریخ انتشار 1989