An automated and standardized neural index to quantify patient-ventilator interaction
نویسندگان
چکیده
INTRODUCTION The aim of this study was to validate an automated, objective and standardized algorithm for quantifying and displaying patient-ventilator interaction. METHODS Using a new method to detect patient-ventilator synchrony, the present study re-analyzed previously acquired and published data from 24 mechanically ventilated adult patients (Colombo et al., Crit Care Med. 2011 Nov;39(11):2452-7). Patient-ventilator interactions were evaluated by comparing ventilator pressure and diaphragm electrical activity (EAdi) waveforms, recorded during pressure support ventilation. The EAdi and ventilator pressure waveforms were analyzed for their timings (manually and automatically determined), and the error between the two waveforms was quantified. A new index of patient-ventilator interaction (NeuroSync index), which is standardized and automated, was validated and compared to manual analysis and previously published indices of asynchrony. RESULTS The comparison of manual and automated detection methods produced high test-retest and inter-rater reliability (Intraclass correlation coefficient = 0.95). The NeuroSync index increased the sensitivity of detecting dyssynchronies, compared to previously published indices, which were found to only detect asynchronies. CONCLUSION The present study introduces an automated method and the NeuroSync index to determine patient-ventilator interaction with a more sensitive analysis method than those previously described. A dashboard-style of graphical display allows a rapid overview of patient-ventilator interaction and breathing pattern at the bedside.
منابع مشابه
Automated patient-ventilator interaction analysis during neurally adjusted non-invasive ventilation and pressure support ventilation in chronic obstructive pulmonary disease
INTRODUCTION Delivering synchronous assist during non-invasive ventilation (NIV) is challenging with flow- or pressure-controlled ventilators, especially in patients with chronic obstructive pulmonary disease (COPD). Neurally adjusted ventilatory assist (NAVA) uses diaphragm electrical activity (EAdi) to control the ventilator. We evaluated patient-ventilator interaction in patients with COPD d...
متن کاملAutomated detection of patient-ventilator asynchrony: new tool or new toy?
Although severe patient-ventilator asynchrony is frequent during invasive and non-invasive mechanical ventilation, diagnosing such asynchronies usually requires the presence at the bedside of an experienced clinician to assess the tracings displayed on the ventilator screen, thus explaining why evaluating patient-ventilator interaction remains a challenge in daily clinical practice. In the prev...
متن کاملTranscutaneous electromyographic respiratory muscle recordings to quantify patient–ventilator interaction in mechanically ventilated children
BACKGROUND To explore the feasibility of transcutaneous electromyographic respiratory muscle recordings to automatically quantify the synchronicity of patient-ventilator interaction in the pediatric intensive care unit. METHODS Prospective observational study in a tertiary paediatric intensive care unit in an university hospital. Spontaneous breathing mechanically ventilated children < 18 yea...
متن کاملPatient–ventilator asynchrony during conventional mechanical ventilation in children
BACKGROUND We aimed (1) to describe the characteristics of patient-ventilator asynchrony in a population of critically ill children, (2) to describe the risk factors associated with patient-ventilator asynchrony, and (3) to evaluate the association between patient-ventilator asynchrony and ventilator-free days at day 28. METHODS In this single-center prospective study, consecutive children ad...
متن کاملAutomated Methods for Estimating Baseflow from Streamflow Records in a Semi Arid Watershed
Understanding of the runoff generation processes is important in understanding the magnitude and dynamics ofgroundwater discharge. However, these processes continue to be difficult to quantify and conceptualize. In this study,two digital filter based separation modules, the Recursive filtering method (RDF) and a generalization of therecursive digital filter (GRDF) were1991–2002 in the Hableh Ro...