Myocardial ischaemia in patients with primary APS: a 13N-ammonia PET assessment.

نویسندگان

  • E Alexánderson
  • A Gómez-León
  • A Vargas
  • J L Romero
  • C Sierra Fernández
  • M Rodriguez Valero
  • L García-Rojas
  • A Meave
  • M-C Amigo
چکیده

OBJECTIVE Evaluate the presence and severity of myocardial ischaemia in a population of asymptomatic patients with primary APS (PAPS) using (13)N-ammonia PET. METHODS We studied 36 patients, 18 with a diagnosis of PAPS and 18 healthy volunteers. All patients underwent a two-phase (rest-stress) (13)N-ammonia PET. Myocardial perfusion images were acquired and then analysed by two experts in the field. RESULTS We found ischaemia in 7/18 asymptomatic PAPS patients (38.8%). The anterolateral wall was the most commonly affected cardiac territory [5/7 PAPS patients (71.4%)]. In a severity analysis, we found that five patients (71.4%) had mild ischaemia, one patient (14.2%) had moderate ischaemia and another one (14.2%) had severe defects. All the healthy volunteers studied showed normal myocardial perfusion images. CONCLUSION An important proportion of PAPS patients, even when asymptomatic, showed myocardial perfusion defects assessed with PET. Most of the ischaemic patients had mild defects and the anterolateral wall was the territory mainly affected.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of global and regional left ventricular function by electrocardiographic gated N-13 ammonia positron emission tomography in patients with coronary artery disease.

BACKGROUND Electrocardiographic gated 13N-ammonia positron emission tomography (PET) enables simultaneous assessment of myocardial blood flow and left ventricular (LV) function. The aim of this study was to assess the accuracy of gated 13N-ammonia PET for evaluating global and regional LV function in patients with coronary artery disease (CAD) in comparison with conventional left ventriculograp...

متن کامل

Gated cardiac 13N-NH3 PET for assessment of left ventricular volumes, mass, and ejection fraction: comparison with electrocardiography-gated 18F-FDG PET.

UNLABELLED The purpose of this study was to evaluate myocardial electrocardiography (ECG)-gated 13N-ammonia (13N-NH3) PET for the assessment of cardiac end-diastolic volume (EDV), cardiac end-systolic volume (ESV), left ventricular (LV) myocardial mass (LVMM), and LV ejection fraction (LVEF) with gated 18F-FDG PET as a reference method. METHODS ECG-gated 13N-NH3 and 18F-FDG scans were perform...

متن کامل

13N ammonia myocardial imaging at rest and with exercise in normal volunteers. Quantification of absolute myocardial perfusion with dynamic positron emission tomography.

Positron emission tomography (PET) was applied to the measurement of myocardial perfusion using the perfusion tracer 13N-labeled ammonia. 13N ammonia was delivered intravenously to 13 healthy volunteers both at rest and during supine bicycle exercise. Dynamic PET imaging was obtained in three cross-sectional planes for 10 minutes commencing with each injection. The left ventricle was divided in...

متن کامل

The combination of 13N-ammonia and 18F-FDG whole-body PET/CT on the same day for diagnosis of advanced prostate cancer

PURPOSE The aim of the study was to evaluate the efficacy of 13N-ammonia and 18F-fluorodeoxyglucose (18F-FDG) PET performed on the same day in the detection of advanced prostate cancer (PC) and its metastases. PATIENTS AND METHODS Twenty-six patients with high-risk PC [Gleason score 8-10 or prostate-specific antigen (PSA)> 20 ng/ml or clinical tumor extension ≥ T2c] were recruited into the st...

متن کامل

The effect of metabolic milieu on cardiac PET imaging using fluorine-18-deoxyglucose and nitrogen-13-ammonia in normal volunteers.

Cardiac PET imaging using 13N-ammonia and 18FDG was performed on 17 normal volunteers in the glucose-loaded and fasted states. PET images (glucose-loaded and fasted) were subjected to qualitative visual analysis using the descriptors: image quality, FDG blood-pool activity, ammonia lung field activity, and clinical interpretability. Glucose-loaded studies had better image quality, diminished FD...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Rheumatology

دوره 47 6  شماره 

صفحات  -

تاریخ انتشار 2008