Diagnostic Accuracy of 4 Commercially Available Semiautomatic Packages for Carotid Artery Stenosis Measurement on CTA.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Semiautomatic measurement of ICA stenosis potentially increases observer reproducibility. In this study, we assessed the diagnostic accuracy and interobserver reproducibility of a commercially available semiautomatic ICA stenosis measurement on CTA and estimated the agreement among different software packages. MATERIALS AND METHODS We analyzed 141 arteries from 90 patients with TIA or ischemic stroke. Manual stenosis measurements were performed by 2 neuroradiologists. Semiautomatic measurements by using 4 methods (3mensio and comparable software from Philips, TeraRecon, and Siemens) were performed by 2 observers. Diagnostic accuracy was estimated by comparing semiautomatic with manual measurements. Interobserver reproducibility and agreement between different packages was assessed by calculation of the intraclass correlation coefficient and Bland-Altman 95% limits of agreement. False-negative classifications were retrospectively inspected by a neuroradiologist. RESULTS There was no significant difference in the diagnostic performance of the 4 semiautomatic methods. The sensitivity for detecting ≥50% and ≥70% degree of stenosis was between 76% and 82% and 46% and 62%, respectively. Specificity and overall diagnostic accuracy were between 92% and 97% and 85% and 90%, respectively. The interobserver intraclass correlation coefficient was between 0.83 and 0.96 for semiautomatic measurements and 0.81 for manual measurement. The limits of agreement between each pair of semiautomatic packages ranged from -18%-24% to -33%-31%. False-negative classifications were caused by ulcerative plaques and observer variation in stenosis and reference measurements. CONCLUSIONS Semiautomatic methods have a low-to-good sensitivity and a good specificity and overall diagnostic accuracy. The high interobserver reproducibility makes semiautomatic stenosis measurement valuable for clinical practice, but semiautomatic measurements should be checked by an experienced radiologist.
منابع مشابه
CT angiographic analysis of carotid artery stenosis: comparison of manual assessment, semiautomatic vessel analysis, and digital subtraction angiography.
BACKGROUND AND PURPOSE To compare multisection CT angiography (CTA) analyzed with source/maximum intensity projection (MIP) images as well as semiautomated vessel analysis software with intra-arterial digital subtraction angiography (DSA) in detection and grading of carotid artery bifurcation stenosis. METHODS Consecutive patients with sonography evidence of a marked internal carotid artery s...
متن کاملLumen segmentation and stenosis quantification of atherosclerotic carotid arteries in CTA utilizing a centerline intensity prior.
PURPOSE The degree of stenosis is an important biomarker in assessing the severity of cardiovascular disease. The purpose of our work is to develop and evaluate a semiautomatic method for carotid lumen segmentation and subsequent carotid artery stenosis quantification in CTA images. METHODS The authors present a semiautomatic stenosis detection and quantification method following lumen segmen...
متن کاملCT angiography for the detection and characterization of carotid artery bifurcation disease.
BACKGROUND AND PURPOSE Computed tomographic angiography (CTA) is a relatively new and minimally invasive method of imaging intracranial and extracranial blood vessels. The main purpose of this study was to compare CTA to the current gold standard of arterial imaging, digital subtraction angiography (DSA), for the detection and quantification of carotid artery bifurcation stenosis. We also compa...
متن کاملSimplification of the residual lumen geometry in measuring carodid stenosis.
Measuring Carotid Stenosis With interest, we read the article by Bartlett et al on measuring carotid artery stenosis with CT angiography (CTA). The authors found excellent correlations between the cross-sectional area of the contrast lumenogram and the narrowest diameter at the site of stenosis as well as between the cross-sectional area of the contrast lumenogram and the calculated area derive...
متن کاملComparison of the carotid stenosis index with CT angiography.
To the Editor: The optimal method for measurement of carotid stenosis remains something of an enigma. Large randomized control trials in symptomatic and asymptomatic carotid stenosis have been based on standardized measurements of carotid stenosis derived from digital subtraction angiography and/or duplex ultrasound. Accordingly, there have been various methods used to measure percent stenosis ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 36 10 شماره
صفحات -
تاریخ انتشار 2015