Detection of immune complexes. The use of radioimmunoassays with Clq and monoclonal rheumatoid factor.

نویسندگان

  • A Gabriel
  • V Agnello
چکیده

This study describes two sensitive, rapid, relatively simple, competitive inhibition radioimmunoassays for detecting immune complex. The tests are based on the inhibition of I125-Clq or I125-monoclonal rheumatoid factor (mRF) binding to an insoluble substrate, IgG-Sepharose. The assays can be performed in 5 h utilizing 10 micronl of serum. Heating of serum is not required and polyclonal rheumatoid factors do not interefere. With the two assays, a wide range of complexes of various size and complement fixing activity can be detected. The Clq test can detect complement fixing Ig complexes larger than 19S, while the mRF tests detect complexes of IgG as small as 8S irrespective of their complement fixing activity. Mouse, rabbit, and human aggregated IgG (agg IgG) can be detected in the Clq test, and human and rabbit agg IgG in the mRF test. As low as 4 microng/ml of isolated human agg IgG can be detected in the Clq test and 0.5 microng/ml in the rheumatoid factor test. Sensitivity is greater for mouse agg IgG. For pathologic sera which must be diluted to eliminate interfering factors, the sensitivity of the assay is approximately 10 times less. The Clq test showed marked inhibition by systemic lupus erythematosus sera with close correlation with CH50 levels and disease activity. The mRF test showed better correlation with rheumatoid arthritis sera. In addition, anionic macromolecules known to react with Clq and other Clq reactants that occur in pathologic sera such as the "low molecular weight" substances in systemic lupus erythematosus are also detected. These reactants are not detectable in the mRF test and can be eliminated in the Clq test by performing the test at higher ionic strength. The tests can be applied to the study of a variety of pathologic states where immune complexes appear to play a role.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Circulating immune complexes in cutaneous vasculitis. Detection with C1q and monoclonal rheumatoid factor.

To investigate the pathogeneic significance of immune complexes in cutaneous vasculitis, 107 patients with various forms of cutaneous vasculitis, including 59 patients with necrotizing (leukocytoclastic) vasculitis (group 1), and 48 patients with lymphocytic vasculitis, or a predominately lymphocytic perivascular infiltrate (group 2), were studied. Immunoglobulins or complement components in cu...

متن کامل

Correlation between IgG class of rheumatoid factors, immune complexes and C-reactive protein in human sera containing RF

We measured the concentration of three immunoglobulin classes of rheumatoid factors (Ig-RFs), C3d binding IgG immune complex (C3d-IC), Clq binding IgG immune complex (Clq-IC) and C-reactive protein (CRP) in 74 samples of human sera with high levels of RF (24.0-2350.0 IU/mI). In sera with high levels of C3d-IC (> 15.0,ug/ml), there was a positive correlation between the levels of CRP and the IgG...

متن کامل

Circulating and intra-articular immune complexes in patients with rheumatoid arthritis. Correlation of 125I-Clq binding activity with clinical and biological features of the disease.

The correlation between the incidence and level of immune complexes in serum and synovial fluid and the various clinical and biological manifestations of rheumatoid arthritis has been studied. Immune complexes were quantitated using a sensitive radioimmunoassay, the 125I-Clq binding test, in unheated native sera and synovial fluids from 50 patients with seropositive (RA +) and 45 with seronegat...

متن کامل

Fall in immune complex levels during gold treatment of rheumatoid arthritis.

Prior to starting gold treatment 30 patients with rheumatoid arthritis had an elevated mean level of circulating immune complexes measured by Clq binding activity. Gold treatment led to an improvement in disease reflected by significant falls in erythrocyte sedimentation rate (p less than 0.001), C-reactive protein (p less than 0.01), Ritchie articular index (p less than 0.001), and duration of...

متن کامل

In vitro methods for detection of circulating immune complexes.

The possible pathologic consequences of the presence of circulating immune complexes in certain disease states has caused considerable attention to be given to the development of laboratory procedures capable of quantitatively measuring the presence of immune complexes in serum. Many assays are available which utilize differing properties of immune complexes for their detection. Examples of ass...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of clinical investigation

دوره 59 5  شماره 

صفحات  -

تاریخ انتشار 1977