Development of a Mass Sensitive Quartz Crystal Microbalance (QCM)-Based DNA Biosensor Using a 50 MHz Electronic Oscillator Circuit

نویسندگان

  • Gonzalo García-Martinez
  • Enrique Alonso Bustabad
  • Hubert Perrot
  • Claude Gabrielli
  • Bogdan Bucur
  • Mathieu Lazerges
  • Daniel Rose
  • Loreto Rodríguez-Pardo
  • José Fariña
  • Chantal Compère
  • Antonio Arnau Vives
چکیده

This work deals with the design of a high sensitivity DNA sequence detector using a 50 MHz quartz crystal microbalance (QCM) electronic oscillator circuit. The oscillator circuitry is based on Miller topology, which is able to work in damping media. Calibration and experimental study of frequency noise are carried out, finding that the designed sensor has a resolution of 7.1 ng/cm(2) in dynamic conditions (with circulation of liquid). Then the oscillator is proved as DNA biosensor. Results show that the system is able to detect the presence of complementary target DNAs in a solution with high selectivity and sensitivity. DNA target concentrations higher of 50 ng/mL can be detected.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In situ QCM DNA-biosensor probe modification

We report on a probe modification of a quartz crystal microbalance (QCM) DNA-biosensor that permits to reversibly change the DNA sequence detected. A QCM DNA-biosensor was designed by immobilization of a 20-base DNA-disulfide probe on the gold-covered quartz surface of a 27 MHz microbalance (9 MHz, third overtone). After immobilization on the gold covered quartz surface, this probe was modified...

متن کامل

Quartz Crystal Microbalance Study of Dna Immobilization and Hybridization for Dna Sensor Development

Piezoelectric materials such as quartz can be used to detect mass change due to their piezoelectric properties. Quartz Crystal Microbalance (QCM) is an extremely sensitive mass sen frequency biosensor mass mea for QCM DNA biosensor was developed. The potential for QCM to be employed as immunosensor sor, capable of measuring sub-nanogram levels by detecting change in the of a quartz crystal reso...

متن کامل

All-Digital Interface ASIC for a QCM-Based Electronic Nose

An all digital interface, application specific integrated circuit (ASIC) has been developed for the control and data sampling of a quartz crystal microbalance (QCM)-based electronic nose. The ASIC is capable of measuring QCM resonant frequency between 0 – 11 MHz with a resolution of 1 Hz and +/1 Hz precision. The ASIC has been used to obtain measurements from polymer coated QCM sensors, in conj...

متن کامل

A High Fundamental Frequency Quartz Crystal Biosensor Integrated into an Electro-wetting-on-dielectrics Based Lab-on-a-chip

We demonstrate the operation of an Electro Wetting on Dielectrics (EWOD) hybrid lab-on-a-chip system by utilizing a Quartz Crystal Microbalance (QCM) resonator as mass-sensitive sensor. We have tested the formation of a phosphorlipid monolayer out of an aqueous buffer suspension onto the integrated sensor. The altered mass load resulted in a shift of the resonance frequencies. Subsequently, the...

متن کامل

Quartz Crystal Microbalance Electronic Interfacing Systems: A Review

Quartz Crystal Microbalance (QCM) sensors are actively being implemented in various fields due to their compatibility with different operating conditions in gaseous/liquid mediums for a wide range of measurements. This trend has been matched by the parallel advancement in tailored electronic interfacing systems for QCM sensors. That is, selecting the appropriate electronic circuit is vital for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2011