Procedures with medical examination

ثبت نشده
چکیده

Carbonic Bath: The bath is prepared by saturating normal or mineral water with carbon dioxid (CO2). The effect of the bath depends on its temperature and on the amount of CO2 in the water. The bath should be hypothermic (28°C – 34°C). The bath is more efficient at lower temperature. An active hyperemia arises in the places where the skin is in a contact with the bath. Capillaries dilate there and the effect is the same as with autotransfusion to the periphery. The blood supply to the skin is sufficient, the perception of cold is decreased and the initial sensation of cold is replaced by a sensation of warmth. With regard to its minimum heat strain the treatment is suitable for many disorders such as heart and vascular diseases or afflictions of nervous or blood circulation systems – but always on medical prescription only.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peripheral Lymphadenopathy: Approach and Diagnostic Tools

Peripheral lymph nodes, located deep in the subcutaneous tissue, clean antigens from the extracellular fluid. Generally, a normal sized lymph node is less than one cm in diameter. Peripheral lymphadenopathy (LAP) is frequently due to a local or systemic, benign, self-limited, infectious disease. However, it could be a manifestation of underlying malignancy. Seventy-five percent of all LAPs are ...

متن کامل

Radiation exposure from diagnostic nuclear medicine examinations in Golestan province

Introduction: The aim of present study was to estimate effective dose from most common procedures performed in nuclear medicine departments of Golestan province. Methods: Data of nuclear medicine procedures performed in 2 nuclear medicine departments in Golestan province were collected during 4 years. Effective dose, collective effective dose and effective dose per examination were calculated ...

متن کامل

“Heidelberg standard examination” and “Heidelberg standard procedures” – Development of faculty-wide standards for physical examination techniques and clinical procedures in undergraduate medical education

The competent physical examination of patients and the safe and professional implementation of clinical procedures constitute essential components of medical practice in nearly all areas of medicine. The central objective of the projects "Heidelberg standard examination" and "Heidelberg standard procedures", which were initiated by students, was to establish uniform interdisciplinary standards ...

متن کامل

Determination of Diagnostic Reference Level in routine Computed radiography examination in north of Iran

Introduction: Digital radiography has a major role in nowadays healthcare system so radiation protection (justification and optimization) is important in this field. Many related organizations to protection suggested to establish national and regional diagnostic reference level for medical procedures. Reference levels are typically set at the 75th percentile of the dose distri...

متن کامل

Optimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD)

Background Increasing the x-ray film to focus distance (FFD), has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. In the previous study, we demonstrated a 32% reduction in absorbed dose is achievable due to increasing the FFD from 100 to 130 cm during pediatric chest radiography. The aim of this study was to examine whether in...

متن کامل

Effect of multisensory stimulation on oxygen saturation in premature infants during eye examination

Background: Eye examination for screening of Retinopathy of Prematurity (ROP), as a painful procedure, causes physiological changes in premature infants. Multisensory stimulation is a non-pharmacological analgesic method which affects physiological measures during painful procedures. Aim: To determine the effect of multisensory stimulation on oxygen saturation in premature infants during eye ex...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016