Radio-frequency-based Determination of Arcing Duration in Hvac Circuit Breakers
نویسنده
چکیده
The arcing duration of a switching operation is a critical input parameter in condition-based switchgear monitoring algorithms. In this paper we propose a new non-intrusive method that directly measures the duration of the electrical arc discharge during current interruption in switchgear. The method relies on coupling of the VHF electric fields generated by the arc. The required hardware used for the measurement is simple and inexpensive, making the proposed methodology potentially commercially viable for application in monitoring systems.
منابع مشابه
Reliability Based Optimal Preventive Maintenance Policy for High Voltage Circuit Breakers in Power Plants
Electric power industry have always try to provide reliable electricity to customers and at the same time decrease system costs. High Voltage circuit-breakers are an essential part of the power network. This study has developed a maintenance and replacement scheduling model for high voltage circuit- breakers that minimize maintenance costs while maintaining the acceptable reliability. This mo...
متن کاملInvestigating Characteristics of N2, CO2 and CF3I in Contrast to High Current Arcs in Circuit Breakers to Choose a Suitable Substitute for SF6
Specific and sensitive operation of circuit breakers makes an individual position for them in power networks. Circuit breakers are at the central gravity of variations and execution operations. Therefore, an optimum operation is the main reason to investigate about new gases to be used in MV and HV circuit breakers instead of SF6. The arc process has enormous complexity because of hydrodynamic ...
متن کاملSpectroscopic On-Line Monitoring of Cu/W Contacts Erosion in HVCBs Using Optical-Fibre Based Sensor and Chromatic Methodology
Contact erosion is one of the most crucial factors affecting the electrical service lifetime of high-voltage circuit breakers (HVCBs). On-line monitoring the contacts' erosion degree is increasingly in demand for the sake of condition based maintenance to guarantee the functional operation of HVCBs. A spectroscopic monitoring system has been designed based upon a commercial 245 kV/40 kA S F 6 l...
متن کاملArc Fault Detection Through Model Reference Estimation
In most arc fault circuit breakers, arc detection is accomplished through the signature analysis of remotely sensed branch currents, with high frequency spectral components being indicative of arcing. This paper presents an alternative approach based upon system identification. A model is assumed for the load on the distribution bus. This model is updated continuously by comparing measured volt...
متن کاملArc Fault Detector
The subject of arc fault detection and circuit interruption has gained a lot of attention in recent years, particularly in the aviation industry. This is primarily due to a spate of in-flight fires which have been linked to faulty electrical systems and wiring on aircraft. Typical causes of faults are wiring chafing, dust build up and moisture [1][2]. Until recently, aircraft circuit breakers, ...