Evaluation of a variable ratio cardioplegia system.

نویسندگان

  • J J Deptula
  • D P Zavadil
  • K A Christensen
  • R T Sydzyik
  • A H Stammers
چکیده

Gish Biomedical has designed a blood cardioplegia delivery system (MyoManager) which is purported to provide rapid control of blood and crystalloid solution ratios for myocardial preservation. The present study was designed to evaluate the ability of this device to provide cardioplegia solutions of specific hematocrit and potassium ion concentrations ([K+]). An in vitro circuit was designed whereby a blood perfusate with a [K+] of 5 mEq/L was mixed with a base crystalloid solution containing 210 mEq/L of K+. Data was collected at several blood to crystalloid ratios (1:1, 4:1, 8:1, 16:1, 25:1), and at four delivery rates (100, 150, 200, 250 ml/min). Predicted and observed values of total cardioplegia volume, hematocrit, crystalloid volume, and [K+] were statistically (ANOVA) analyzed, and statistical significance accepted at p 0.05. There were no statistically significant differences observed at any flows or ratios in hematocrit. However, at 100 ml/min flow rates, the crystalloid delivery volume difference of 2.4 +/- 2.0 ml was significantly higher than that observed at 250 ml/min, 1.5 +/- 1.5 ml (p < 0.02) and at 200 ml/min flow rates, 1.5 +/- 1.6 ml (p < 0.02). There was no statistical significance in [K+] difference between flows across all ratios. However, within ratios, a significant difference in [K+] at 100 ml/min, 1:1 blood to crystalloid ratio, was observed (p < 0.0001) versus all other ratios and flows. The only statistically significant difference that was shown in total cardioplegia delivery volume was observed between 100 and 200 ml/min (p < 0.04) when analyzed across all ratios. The data suggests that the MyoManager effectively provides precise control of [K+] and hematocrit at cardioplegia flows greater than 100 ml/min.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An in vitro evaluation of a self-contained cardioplegia delivery device.

Focus on improved myocardial protection has prompted the development of delivery systems which can accommodate the demands of increasingly refined cardioprotective strategies. The purpose of this study was to evaluate the Sorin Blood Cardioplegia Console (BCC) for accuracy and precision in the delivery of cardioplegia solutions. An in vitro model was designed to evaluate the following performan...

متن کامل

Evaluation of a new generation cardioplegia administration system.

The delivery of cardioplegia has traditionally been constrained by the physical limitations of the mechanical devices in use, yet myocardial protective strategies may vary both according to patient condition and operative requirements. The need for a cardioplegia administration device that allows flexibility and safety is evident. The purpose of this study was to evaluate the performance of the...

متن کامل

The Cardioprotective Effects of N acetylcysteine as an Additive to the Blood Cardioplegia During Coronary Artery Bypass Grafting

Introduction: During coronary artery bypass graft (CABG) surgery with cardiopulmonary bypass (CPB), the role of cardioplegic solution which results in cardiac arrest, is critical. This study was planned to evaluate the clinical impacts of N acetylcysteine (NAC) enriched cold-blood cardioplegia on early reperfusion injury in patients with ischaemic heart disease undergoing CABG Methods: In a...

متن کامل

An Evaluation of an Adaptive Generalized Likelihood Ratio Charts for Monitoring the Process Mean

When the objective is quick detection both small and large shifts in the process mean with normal distribution, the generalized likelihood ratio (GLR) control charts have better performance as compared to other control charts. Only the fixed parameters are used in Reynolds and Lou’s presented charts. According to the studies, using variable parameters, detect process shifts faster than fixed pa...

متن کامل

Throughput Improvement of STS-Based MC DS-CDMA System with Variable Spreading Factor

The throughput enhancement of Space-Time Spreading (STS)-based Multicarrier Direct Sequence Code Division Multiple Access (MC DS-CDMA) system is investigated in this paper. Variable Spreading Factor (VSF) is utilized to improve the data throughput of the system. In this contribution, an analytical approach is proposed to compute a new expression for the Bit Error Rate (BER) performance of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 28 4  شماره 

صفحات  -

تاریخ انتشار 1996