Current failure mechanisms after knee arthroplasty have changed: polyethylene wear is less common in revision surgery.
نویسندگان
چکیده
BACKGROUND The present study was designed to clarify which underlying indications can be currently considered the main reasons for failure after total knee arthroplasty as a function of time. METHODS We conducted a retrospective study that included all first revisions of total knee replacements during 2005 to 2010 at two high-volume arthroplasty centers. A revision was defined as the replacement of at least one prosthetic component. In the descriptive analysis, polyethylene wear, aseptic loosening, periprosthetic infection, malalignment, instability, arthrofibrosis, extensor mechanism deficiency, periprosthetic fracture, and retropatellar arthritis were given as the failure mechanism associated with an early, intermediate, or late time interval (less than one year, one to three years, and more than three years, respectively) after the index total knee arthroplasty. RESULTS Three hundred and fifty-eight revision total knee arthroplasties were included. Of those revisions, 19.8% were performed within the first year after the index arthroplasty. The most common indications for revision, besides aseptic loosening (21.8%), were instability (21.8%), malalignment (20.7%), and periprosthetic infection (14.5%). Revisions due to polyethylene wear (7%) rarely occurred. In the early failure group, the primary causes of revision were periprosthetic infection (26.8%) and instability (23.9%). In the intermediate group, instability (23.3%) and malalignment (29.4%) required revision surgery, whereas late failure mechanisms were aseptic loosening (34.7%), instability (18.5%), and polyethylene wear (18.5%). CONCLUSIONS Aseptic loosening, instability, malalignment, and periprosthetic infection continue to be the primary failure mechanisms leading to revision surgery. Contrary to previous literature, the results in the present study showed a substantial reduction in implant-associated revisions such as those due to polyethylene wear. Failure mechanisms that occur persistently early and in the intermediate term, such as periprosthetic infection, instability, and malalignment, remain common causes of revision surgery. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
منابع مشابه
Causes of Failure after Total Knee Arthroplasty in Osteoarthritis Patients 55 Years of Age or Younger
PURPOSE To identify the modes of failure after total knee arthroplasty (TKA) in patients >55 years of age and to compare with those >55 years of age in patients who underwent revision TKA. MATERIALS AND METHODS We retrospectively reviewed 256 revision TKAs among patients who underwent TKA for knee osteoarthritis between January 1992 and December 2012. The causes of TKA failure were analyzed a...
متن کاملDevelopment and Validation of a Wear Model to Predict Polyethylene Wear in a Total Knee Arthroplasty: A Finite Element Analysis
Ultra-high molecular weight polyethylene (UHMWPE) wear in total knee arthroplasty (TKA) components is one of the main reasons of the failure of implants and the consequent necessity of a revision procedure. Experimental wear tests are commonly used to quantify polyethylene wear in an implant, but these procedures are quite expensive and time consuming. On the other hand, numerical models could ...
متن کاملParesis of the Peroneal Nerve: A Rare But Severe Long-term Complication of Polyethylene Wear in Knee Arthroplasty.
One of the most important limiting factors in the long-term success of total knee arthroplasty is polyethylene wear. Particles of the polyethylene inserts have been shown to elicit a foreign body response, which produces bone resorption and osteolysis, ultimately leading to loosening and component failure. The authors report on a case of an elderly patient who underwent a total knee arthroplast...
متن کاملObservations on retrieved humeral polyethylene components from reverse total shoulder arthroplasty.
HYPOTHESIS Analyses of polyethylene components retrieved at revision of total knee, hip, and shoulder replacements have been used to study the effect of design, patient, and surgical factors on initial implant performance, but no studies have reported similar types of findings in retrieved humeral polyethylene components in reverse total shoulder arthroplasty. Our hypothesis is that while the c...
متن کاملResults of Revision Surgery and Causes of Unstable Total Knee Arthroplasty
BACKGROUND The aim of this study was to evaluate causes of unstable total knee arthroplasty and results of revision surgery. METHODS We retrospectively reviewed 24 knees that underwent a revision arthroplasty for unstable total knee arthroplasty. The average follow-up period was 33.8 months. We classified the instability and analyzed the treatment results according to its cause. Stress radiog...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. American volume
دوره 97 9 شماره
صفحات -
تاریخ انتشار 2015