Fast , Pseudo - Continuous Arterial Spin Labeling for Functional Imaging Using a Two - Coil System by Luis
نویسندگان
چکیده
2 Abstract A fast, two-coil pseudo-continuous labeling scheme is presented. The new scheme permits collection of a multi-slice subtraction pair in less than three seconds, depending on the subject's arterial transit times. The method consists of acquisition of both the control and tag images immediately after a labeling period that matches the arterial transit time. The theoretical basis of the technique, as well as simulations of the signal during changes in both transit time and perfusion, are presented. Experimental data from functional imaging experiments was collected to demonstrate the technique and its characteristics.
منابع مشابه
Fast, pseudo-continuous arterial spin labeling for functional imaging using a two-coil system.
A fast, two-coil, pseudo-continuous labeling scheme is presented. This new scheme permits the collection of a multislice subtraction pair in <3 s, depending on the subject's arterial transit times. The method consists of acquiring both control and tag images immediately after a labeling period that matches the arterial transit time. The theoretical basis of the technique, and simulations of the...
متن کاملReal-time functional MRI using pseudo-continuous arterial spin labeling.
The first implementation of real-time acquisition and analysis of arterial spin labeling-based functional magnetic resonance imaging time series is presented in this article. The implementation uses a pseudo-continuous labeling scheme followed by a spiral k-space acquisition trajectory. Real-time reconstruction of the images, preprocessing, and regression analysis of the functional magnetic res...
متن کاملContinuous arterial spin labeling using a local magnetic field gradient coil.
Continuous arterial spin labeling (ASL) using a locally induced magnetic field gradient for adiabatic inversion of spins in the common carotid artery of human volunteers is demonstrated. The experimental setup consisted of a helmet resonator for imaging, a circular RF surface coil for labeling, and gradient loops to produce a magnetic field gradient. A spin-echo (SE) echo-planar imaging (EPI) s...
متن کاملContinuous arterial spin labeling using a train of adiabatic inversion pulses.
PURPOSE To develop a simple and robust magnetic resonance imaging (MRI) pulse sequence for the quantitative measurement of blood flow in the brain and cerebral tumors that has practical implementation advantages over currently used continuous arterial spin labeling (CASL) schemes. MATERIALS AND METHODS Presented here is a single-coil protocol that uses a train of hyperbolic secant inversion p...
متن کاملBackground suppression in arterial spin labeling MRI with a separate neck labeling coil.
In arterial spin labeling (ASL) MRI to measure cerebral blood flow (CBF), pair-wise subtraction of temporally adjacent non-labeled and labeled images often can not completely cancel the background static tissue signal because of temporally fluctuating physiological noise. While background suppression (BS) by inversion nulling improves CBF temporal stability, imperfect pulses compromise CBF cont...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -