Preferential interaction between DNA and small ions in mixed-size counterion systems: Monte Carlo simulation and density functional study.

نویسندگان

  • Ke Wang
  • Yang-Xin Yu
  • Guang-Hua Gao
  • Guang-Sheng Luo
چکیده

Competitive binding between counterions around DNA molecule is characterized using the preferential interaction coefficient of individual ion in single and mixed electrolyte solutions. The canonical Monte Carlo (MC) simulation, nonlinear Poisson-Boltzmann (PB) equation, and density functional theory (DFT) proposed in our previous work [Wang, Yu, Gao, and Luo, J. Chem. Phys. 123, 234904 (2005)] are utilized to calculate the preferential interaction coefficients. The MC simulations and theoretical results show that for single electrolyte around DNA, the preferential interaction coefficient of electrolyte decreases as the cation size is increased, indicating that the larger cation has less accumulation ability in the vicinity of DNA. For the mixed electrolyte solution, it is found that cation diameter has a significant effect on the competitive ability while anion diameter has a negligible effect. It proves that the preferential interaction coefficients of all ions decrease as the total ionic concentration is increased. The DFT generally has better performance than the PB equation does when compared to the MC simulation data. The DFT behaves quite well for the real ionic solutions such as the KCl-NaCl-H2O, NaCl-CaCl2-H2O, and CaCl2-MgCl2-H2O systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Density-functional theory and Monte Carlo simulation study on the electric double layer around DNA in mixed-size counterion systems.

A density-functional approach and canonical Monte Carlo simulations are presented for describing the ionic microscopic structure around the DNA molecule immersed in mixed-size counterion solutions. In the density-functional approach, the hard-sphere contribution to the Helmholtz energy functional is obtained from the modified fundamental measure theory [Y.-X. Yu and J. Z. Wu, J. Chem. Phys. 117...

متن کامل

Simulation study of the performance of a biologically sensitive field effect transistor

The transformation of biochemical information into a physical or chemical signal is the basic idea behind a biosensor. The efficient detection of charged biomolecules by biosensor with appropriate device has caught tremendous research interest in the present decade. The present work is related to the simulation study of the performance of a functionalized surface of a biologically sensitive fie...

متن کامل

Simulation study of the performance of a biologically sensitive field effect transistor

The transformation of biochemical information into a physical or chemical signal is the basic idea behind a biosensor. The efficient detection of charged biomolecules by biosensor with appropriate device has caught tremendous research interest in the present decade. The present work is related to the simulation study of the performance of a functionalized surface of a biologically sensitive fie...

متن کامل

Evaluation of dose distribution of 12C ion beam in radiotherapy by FLUKA as a Monte Carlo simulation Code

Introduction: Nowadays, the use of heavy ion beams in cancer therapy have been developed worldwide.   Materials and Methods: It requires accurate understanding of the complex processes of ion interaction with matter, as it is the calculation the relative dose & range of these ions in matter. In the present study we used FLUKA as a numerical Monte Carlo simula...

متن کامل

Dose Calculations for Lung Inhomogeneity in High-Energy Photon Beams and Small Beamlets: A Comparison between XiO and TiGRT Treatment Planning Systems and MCNPX Monte Carlo Code

Introduction Radiotherapy with small fields is used widely in newly developed techniques. Additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. In the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against Monte Carlo method. Materials and Methods Siemens Once or linea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of chemical physics

دوره 126 13  شماره 

صفحات  -

تاریخ انتشار 2007