Polished, tapered stems are now widely used for cemented total hip replacement and many such designs have been introduced. However, a change in stem geometry may have a profound influence on stability. Stems with a wide, rectangular proximal section may be more stable than those which are narrower proximally. We examined the influence of proximal geometry on stability by comparing the two-year migration of the Exeter stem with a more recent design, the CPS-Plus, which has a wider shoulder and a more rectangular cross-section. The hypothesis was that these design features would increase rotational stability. Both stems subsided approximately 1 mm relative to the femur during the first two years after implantation. The Exeter stem was found to rotate into valgus (mean 0.2 degrees , sd 0.42 degrees ) and internally rotate (mean 1.28 degrees , sd 0.99 degrees ). The CPS-Plus showed no significant valgus rotation (mean 0.07 [correction] degrees, sd 0.29 [correction] degrees ) or internal rotation (mean -0.03 degrees , sd 0.75 degrees ). A wider, more rectangular cross-section improves rotational stability and may have a better long-term outcome.
منابع مشابه
In vitro comparison of the effects of rough and polished stem surface finish on pressure generation in cemented hip arthroplasty
BACKGROUND AND PURPOSE High pressures around implants can cause bone lysis and loosening. We investigated how pressures are generated around cemented femoral stems. METHOD We compared the pressures generated by rough and polished tapered stems at their cement interfaces, in an in vitro model, before and after 1 million load cycles. RESULTS At the start of the study, the loading of both poli...
متن کاملIn vitro influence of stem surface finish and mantle conformity on pressure generation in cemented hip arthroplasty
BACKGROUND AND PURPOSE Under physiological loads, debonded cemented femoral stems have been shown to move within their cement mantle and generate a fluid pump that may facilitate peri-prosthetic osteolysis by pressurizing fluid and circulating wear debris. The long-term physiological loading of rough and polished tapered stems in vitro has shown differences in performance, with greater interfac...
متن کاملSubstantially higher prevalence of postoperative periprosthetic fractures in octogenarians with hip fractures operated with a cemented, polished tapered stem rather than an anatomic stem
Background and purpose - Recent studies have demonstrated a high incidence of postoperative periprosthetic femoral fracture (PPF) in elderly patients treated with 2 commonly used cemented, polished tapered stems. We compared the prevalence and incidence rate of PPF in a consecutive cohort of octagenerians with femoral neck fractures (FNFs) treated with either a collarless, polished tapered (CPT...
متن کاملFive-year prospective clinical and radiological results of a new cannulated cemented polished Tri-Taper femoral stem.
We describe the results at five years of a prospective study of a new tri-tapered polished, cannulated, cemented femoral stem implanted in 51 patients (54 hips) with osteoarthritis. The mean age and body mass index of the patients was 74 years and 27.9, respectively. Using the anterolateral approach, half of the stems were implanted by a consultant orthopaedic surgeon and half by six different ...
متن کاملThe influence of cement thickness on stem subsidence and cement creep in a collarless polished tapered stem
OBJECTIVES Favourable results for collarless polished tapered stems have been reported, and cement creep due to taper slip may be a contributing factor. However, the ideal cement thickness around polished stems remains unknown. We investigated the influence of cement thickness on stem subsidence and cement creep. METHODS We cemented six collarless polished tapered (CPT) stems (two stems each ...