Redesign process of a 765 kVRMS AC substation connector by means of 3D-FEM simulations

نویسندگان

  • Joan Hernández-Guiteras
  • Jordi-Roger Riba Ruiz
  • Luis Romeral
چکیده

This paper shows the capabilities of applying the three-dimensional finite element method (3D-FEM) for designing complex-shaped substation connectors to operate at 765 kVRMS AC. To check this methodology, it was analyzed the feasibility of upgrading a 400 kVRMS substation connector to operate at 765 kVRMS. However, both experimental and simulation results conducted according to the ANSI/NEMA CC 1-2009 standard concluded that although it passed the visual corona test, to ensure a wide safety margin it was desirable an improvement of the electrical behavior of such connector. It was shown that FEM results allowed detecting the peak stress points of the connector regarding the electrical stress thus allowing applying a corrective action. Then, two possible solutions were analyzed, i.e. the use of corona shields and the redesign of the connector assisted by 3D-FEM simulations. Results presented in this work show that both approaches have an excellent behavior in reducing the electric field strength on the connector surface. However, to make the final decision, the production cost of both alternatives was analyzed, thus favoring the redesign option. Next, the redesigned version of the substation connector was manufactured and tested. Experimental results conducted in a high voltage laboratory verified the effectiveness of the methodology and the potential of the proposed system to act as an advanced design tool for optimizing the behavior of complex-shaped substation connectors. Thus, this system allows assisting efficiently the design process while permitting constraining the economic costs. 2013 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-Dimensional Finite-Element Analysis of the Short-Time and Peak Withstand Current Tests in Substation Connectors

Power devices intended for high-voltage systems must be tested according to international standards, which includes the short-time withstand current test and peak withstand current test. However, these tests require very special facilities which consume huge amounts of electrical power. Therefore, mathematical tools to simulate such tests are highly appealing since they allow reproducing the el...

متن کامل

A 3D elasto-plastic FEM program developed for reservoir Geomechanics simulations: Introduction and case studies

The development of yielded or failure zone due to an engineering construction is a subject of study in different disciplines. In Petroleum engineering, depletion from and injection of gas into a porous rock can cause development of a yield zone around the reservoir. Studying this phenomenon requires elasto-plastic analysis of geomaterial, in this case the porous rocks. In this study, which is a...

متن کامل

Finite Element Analysis to Predict Temperature Rise Tests in High-Capacity Substation Connectors

In the last years there has been a considerable increase in electricity consumption and generation from renewable sources, especially wind and solar photovoltaic. This phenomenon has increased the risk of line saturation with the consequent need of increasing the capacity of some power lines. Considering the high cost and the time involved in installing new power lines, the difficulty in acquir...

متن کامل

Salinity Effect on the Corona Onset for a 765 Kv Ac Substation Connector

Outdoor substations placed in coastal areas are affected by saline environments. In the technical literature it is found extensive information regarding insulations problems in presence of saline environments [1]. The accumulation of salts and other contaminants promotes the onset of partial discharges on the devices subjected to very high voltages. Insulators are also affected by this phenomen...

متن کامل

New geometry for TCP: severe plastic deformation of tubes

Since tubes are widely used for different industrial applications, processing of tubes by the Severe Plastic Deformation (SPD) method has been the target of different attempts. Among these attempts, development of SPD processes for tubes based on Equal Channel Angular Pressing (ECAP) has been more successful. As an illustration, Tube Channel Pressing (TCP) has been presented as an attractive SP...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Simulation Modelling Practice and Theory

دوره 42  شماره 

صفحات  -

تاریخ انتشار 2014