Hemoglobin parameters from diffuse reflectance data.
نویسندگان
چکیده
Tissue vasculature is altered when cancer develops. Consequently, noninvasive methods of monitoring blood vessel size, density, and oxygenation would be valuable. Simple spectroscopy employing fiber optic probes to measure backscattering can potentially determine hemoglobin parameters. However, heterogeneity of blood distribution, the dependence of the tissue-volume-sampled on scattering and absorption, and the potential compression of tissue all hinder the accurate determination of hemoglobin parameters. We address each of these issues. A simple derivation of a correction factor for the absorption coefficient, μa, is presented. This correction factor depends not only on the vessel size, as others have shown, but also on the density of blood vessels. Monte Carlo simulations were used to determine the dependence of an effective pathlength of light through tissue which is parameterized as a ninth-order polynomial function of μa. The hemoglobin bands of backscattering spectra of cervical tissue are fit using these expressions to obtain effective blood vessel size and density, tissue hemoglobin concentration, and oxygenation. Hemoglobin concentration and vessel density were found to depend on the pressure applied during in vivo acquisition of the spectra. It is also shown that determined vessel size depends on the blood hemoglobin concentration used.
منابع مشابه
DIFFUSE REFLECTANCE MEASUREMENTS FROM DIFFERENT SURFACES
Relative diffuse reflection measurements from the original and ground surfaces using a He-Ne laser are reported. The intensity measurements for the metallic, transparent dielectric, matte plastic surfaces and colored papers are presented. Our results indicate that among metallic surfaces tested, aluminum has the highest diffuse reflectance; while the original stainless steel surface shows the l...
متن کاملSpectral-profile-based algorithm for hemoglobin oxygen saturation determination from diffuse reflectance spectra
Variations of hemoglobin (Hb) oxygenation in tissue provide important indications concerning the physiological conditions of tissue, and the data related to these variations are of intense interest in medical research as well as in clinical care. In this study, we derived a new algorithm to estimate Hb oxygenation from diffuse reflectance spectra. The algorithm was developed based on the unique...
متن کاملEstimating Reflectance Parameters from Saturated Spectral Images
Since commercial image detectors, such as charge-coupled device (CCD) cameras, have a limited dynamic range, it is difficult to obtain images that really are unsaturated, as a result of which the reflectance parameters may be inaccurately estimated. To solve this problem, we describe a method to estimate reflectance parameters from saturated spectral images. We separate reflection data into dif...
متن کاملRapid ratiometric determination of hemoglobin concentration using UV-VIS diffuse reflectance at isosbestic wavelengths
We developed a ratiometric method capable of estimating total hemoglobin concentration from optically measured diffuse reflectance spectra. The three isosbestic wavelength ratio pairs that best correlated to total hemoglobin concentration independent of saturation and scattering were 545/390, 452/390, and 529/390 nm. These wavelength pairs were selected using forward Monte Carlo simulations whi...
متن کاملMonte Carlo-based inverse model for calculating tissue optical properties. Part II: Application to breast cancer diagnosis.
The Monte Carlo-based inverse model of diffuse reflectance described in part I of this pair of companion papers was applied to the diffuse reflectance spectra of a set of 17 malignant and 24 normal-benign ex vivo human breast tissue samples. This model allows extraction of physically meaningful tissue parameters, which include the concentration of absorbers and the size and density of scatterer...
متن کاملRe-evaluation of model-based light-scattering spectroscopy for tissue spectroscopy.
Model-based light scattering spectroscopy (LSS) seemed a promising technique for in-vivo diagnosis of dysplasia in multiple organs. In the studies, the residual spectrum, the difference between the observed and modeled diffuse reflectance spectra, was attributed to single elastic light scattering from epithelial nuclei, and diagnostic information due to nuclear changes was extracted from it. We...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 19 3 شماره
صفحات -
تاریخ انتشار 2014