Fixation of metatarsal fracture with bone plate in a dromedary heifer

نویسندگان

  • S.A. Siddiqui
  • M.I. Siddiqui
  • M.N. Telfah
  • S. Hashmi
چکیده

An oblique fracture of the distal third of the right metatarsus in a three-year-old dromedary heifer weighing about 300 kilograms was immobilized with a 4.5 mm broad-webbed 12-hole dynamic compression bone plate and two interfragmental compression screws. The animal showed slight lameness after 16 weeks of surgery that disappeared after removal of the plate. The result was quite encouraging and the fracture healed in 16 weeks without major complications. It is concluded that the fracture of this bone can be successfully handled with bone plating at least in young, light weight animals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Locking compression plate distal ulna hook plate fixation versus intramedullary screw fixation for displaced avulsion fifth Metatarsal Base fractures: a comparative retrospective cohort study

BACKGROUND Intramedullary screw (IMS) fixation was wildly used in fifth metatarsal base fractures (FMBFs) and the results were satisfactory. However, in the comminuted osteoporosis or small displaced avulsion FMBFs, anatomical reduction and stable fixation could not be achieved with IMS. The Locking Compression Plate (LCP) distal ulna hook plate fixation was a novel alternative fixation method....

متن کامل

Management of Bilateral Mandibular Fractures Using Intraoral Unilateral Application of Bone Plates in the Dromedary Camel

A clinical study to evaluate unilateral application of 10 holes dynamic compression plates (DCPs) for the treatment of bilateral fracture of the mandible insingle-humped camels. Six cases of typical mandibular fractures in the dromedary camel were treated by unilateral application of 3.5 mm 10holes DCP. Restrained of camels was performed with deep sedation using xylazine hydrochloride and ketam...

متن کامل

Biomechanical In Vitro - Stability Testing on Human Specimens of a Locking Plate System Against Conventional Screw Fixation of a Proximal First Metatarsal Lateral Displacement Osteotomy

INTRODUCTION The aim of this study was to examine resistance to angulation and displacement of the internal fixation of a proximal first metatarsal lateral displacement osteotomy, using a locking plate system compared with a conventional crossed screw fixation. MATERIALS AND METHODOLOGY Seven anatomical human specimens were tested. Each specimen was tested with a locking screw plate as well a...

متن کامل

Treatment of Displaced Sacroiliac Fracture Using the Lateral Window for Short Plate Buttress Reduction and Percutaneous Sacroiliac Screw Fixation.

       Fractures through the sacroiliac joint are very challenging to treat, technically difficult to reduce through closed methods on account of the multiaxial displacement of fractures fragments, frequently occur in very unwell patients, and have poor outcomes if malreduction is present. We describe a technique utilising the lateral window and a short buttress plate to reduce and stabilize th...

متن کامل

The biomechanical study of the influence to the forefoot plantar pressure of the first tarsometatarsal joint fracture-dislocation fixed by three different implants

OBJECTIVES To study the influence of forefoot plantar pressure of the first tarsometatarsal joint fracture-dislocation by three different implants to provide experimental reference in selecting implants. METHODS Eight fresh foot specimens were made into the models of the first tarsometatarsal joint fracture-dislocation, which were fixed with 3.5 mm cortical screw, 1/4 tubular plate and compre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2013