Lc-ms Instrument Calibration
نویسنده
چکیده
As analytical and bioanalytical methods must be validated before using them for routine sample analysis and after changing method parameters (see Chapter 8), instruments such as liquid chromatography coupled with mass spectrometry (LCMS) or tandem mass spectrometry (LC-MS/MS), which are utilized to perform the analysis, should be calibrated and qualified. In addition, an instrument’s performance should be tested for suitability prior to use on practically a day-to-day basis. For Good Laboratory Practice (GLP) studies, any equipment (instrument and any computer system used with it) must be tested according to the documented specifications. GLP regulations, which were issued by the U.S. Food and Drug Administration (FDA) in 1976, apply specifically to nonclinical studies used for Investigational New Drug (IND) registration. Shortly after the FDA introduced GLP regulations, the Organization for Economic Cooperation and Development (OECD) published a compilation of Good Laboratory Practices. OECD member countries have since incorporated GLP into their own legislation. In Europe, the Commission of the European Economic Community (EEC) has made efforts to harmonize the European laws. In general, instrument calibration is part of the regulatory compliance for worldwide drug submission. FDA GLP Chapter 21 of the Code of Federal Regulations Part 58 (CFR 21 Part 58) [1] deals with the
منابع مشابه
LC-MS data analysis for differential protein expression detection.
In proteomic studies, liquid chromatography coupled with mass spectrometry (LC-MS) is a common platform to compare the abundance of various peptides that characterize particular proteins in biological samples. Each LC-MS run generates data consisting of thousands of peak intensities for peptides represented by retention time (RT) and mass-to-charge ratio (m/z) values. In label-free differential...
متن کاملInterlaboratory agreement of insulin-like growth factor 1 concentrations measured by mass spectrometry.
BACKGROUND Insulin-like growth factor 1 (IGF-1)(7) is a key mediator of growth hormone (GH) action and a well-characterized biomarker of GH abuse. Current immunoassays for IGF-1 suffer from poor concordance between platforms, which makes comparison of results between laboratories difficult. Although previous work has demonstrated good interlaboratory imprecision of LC-MS/MS methods when plasma ...
متن کاملBio-analytical Method Development and Validation for Omeprazole Using Lc-ms/ms
Analytical methods employed for the determination of drugs and metabolites in biological matrices such as urine, plasma and serum are essential throughout drug discovery and development. It is well-known that, analytical techniques are constantly undergoing change and improvements and each analytical method has its own characteristics which may vary from analyte to analyte at different conditio...
متن کاملThe march of the masses.
The growth of mass spectrometry and more specifically liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) continues to accelerate in the clinical laboratory. A recent publication (1 ) provides readers with the opportunity to see where we have been, offering examples of how LC-MS/MS has impacted diagnostic care (steroids and clinical toxicology); where we are (pain management, p...
متن کاملMethod development for simultaneous determination of 41 pesticides in rice using LC-MS/MS technique and its application for the analysis of 60 rice samples collected from Tehran market
For the first time, a multi-residue methodfor simultaneous determination of 41LC-amenable pesticides in rice, belonging to different chemical classes has been developed in Iran by LC-MS/MS. The pesticides were analyzed simultaneously in a single run using positive electrospray ionization with multiple reaction monitoring (MRM) after extraction with slightly modified QuEChERS method. The calibra...