Fault Diagnosis for Non - minimum Phase Systems using X m Optimization
نویسندگان
چکیده
Analysis and design algorithms for residual generators for non minimum phase systems are given. It is shown that Rm optimization of residual generators applied directly to systems including non m i n i u m phase zeros can be very conservative. To remove this conservatism in the H, optimization of the residual generators, a factorization of the non minimum phase system into a minimum phase part and an all-pass factor including the non minimum phase zeros can be applied. The optimization of the residual generator can then be done with respect to the minimum phase part of the system only. It is shown that the effect from the all-pass factor will not affect the 2-norm of the residual vector.
منابع مشابه
Fault Diagnosis for Non-minimum Phase Systems usingH∞ Optimization
Analysis and design algorithms for residual generators for non minimum phase systems are given. It is shown that H∞ optimization of residual generators applied directly to systems including non minimum phase zeros can be very conservative. To remove this conservatism in theH∞ optimization of the residual generators, a factorization of the non minimum phase system into a minimum phase part and a...
متن کاملApplication of Signal Processing Tools for Fault Diagnosis in Induction Motors-A Review-Part II
The use of efficient signal processing tools (SPTs) to extract proper indices for the fault detection in induction motors (IMs) is the essential part of any fault recognition procedure. The 2nd part of this two-part paper is, in turn, divided into two parts. Part two covers the signal processing techniques which can be applied to non-stationary conditions. In this paper, all utilized SPTs for n...
متن کاملOptimal Current Meter Placement for Accurate Fault Location Purpose using Dynamic Time Warping
This paper presents a fault location technique for transmission lines with minimum current measurement. This algorithm investigates proper current ratios for fault location problem based on thevenin theory in faulty power networks and calculation of short circuit currents in each branch. These current ratios are extracted regarding lowest sensitivity on thevenin impedance variations of the netw...
متن کاملWaveform Design using Second Order Cone Programming in Radar Systems
Transmit waveform design is one of the most important problems in active sensing and communication systems. This problem, due to the complexity and non-convexity, has been always the main topic of many papers for the decades. However, still an optimal solution which guarantees a global minimum for this multi-variable optimization problem is not found. In this paper, we propose an attracting met...
متن کاملOn-line references reshaping and control reconfiguration for non-minimum phase
In this paper we consider the problem of graceful performance degradation, for affine non-minimum phase nonlinear systems. The method is an optimization based scheme, that gives a constructive way to re-shape on-line the output reference for the post-fault system, and explicitly take into account the actuators and states saturations. The on-line output reference reshaping is associated with an ...
متن کامل