Treatment of cellulite with a bipolar radiofrequency, infrared heat, and pulsatile suction device: a pilot study.

نویسندگان

  • Rungsima Wanitphakdeedecha
  • Woraphong Manuskiatti
چکیده

BACKGROUND Very few therapeutic options have proven effective in the treatment of cellulite. AIMS To evaluate the effectiveness and adverse effects of a bipolar radiofrequency (RF), infrared (IR) heat and pulsatile suction device for the treatment of cellulite. METHODS Twelve subjects were treated with the RF-light-based device. All subjects were treated twice weekly for a total number of eight to nine treatments. Subjects were evaluated using standardized photographs, and measurements of body weight and circumference of treatment sites at baseline, immediately after the last treatment, and four weeks and one year after the last treatment. Clinical improvement scores of comparable photographs using a quartile grading scale (0 = <25%, 1 = 25-50%, 2 = 51-75%, 3 = >75% improvement) were judged independently by two non-treating dermatologists after the series of treatment. RESULTS The average body weights at baseline, immediately after the last treatment, and four weeks and one year after the complete treatment were 56.30, 56.05, 56.23, and 56.53 kg, respectively. The average circumferential reductions of the abdomen and thigh at the last treatment visit were 5.17 +/- 1.04 cm (6.32%+/- 1.82%) and 3.50 +/- 2.16 cm (6.23 +/- 3.58%), respectively. At four weeks after the last treatment, the average circumferential reductions of the abdomen and thigh were sustained at 3.17 +/- 2.75 cm (4.04%+/- 3.69%) and 3.50 +/- 2.04 cm (6.26%+/- 3.52%), respectively. At one year follow-up visit, the average circumferential reductions of the abdomen and thigh were maintained at 3.83 +/- 0.76 cm (4.64%+/- 1.15%) and 3.13 +/- 3.54 (5.50%+/- 6.12%), respectively. Average clinical improvement scores of the abdomen and thigh after the series of treatments were 0.75 (corresponding to approximately 25% improvement), and 1.75 (corresponding to approximately 50% improvement), respectively. CONCLUSIONS A bipolar RF, IR heat and pulsatile suction device provides a beneficial effect on reduction of abdomen and thigh circumference, and smoothening of the cellulite.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cellulite treatment using a novel combination radiofrequency, infrared light, and mechanical tissue manipulation device.

BACKGROUND Most post-pubertal women exhibit cellulite, particularly in the thigh and buttock regions. The prevalence of cellulite has led to many attempts at treatment, including a variety of topical solutions, massage-based therapies, and surgical techniques--most with suboptimal clinical effects. The purpose of this controlled study was to evaluate a novel combination device involving radiofr...

متن کامل

Clinical, laboratory, and MRI analysis of cellulite treatment with a unipolar radiofrequency device.

BACKGROUND Cellulite is seen in more than 85% of postpubertal women. Recent studies show that bipolar radiofrequency and low-level laser devices can produce mild skin tightening of cellulite. OBJECTIVE The primary objective was to determine if a novel unipolar, more deeply penetrating, radiofrequency device can promote better skin tightening with fewer treatments than is seen with previously ...

متن کامل

Circumference reduction and cellulite treatment with a TriPollar radiofrequency device: a pilot study.

BACKGROUND A wide variety of treatments for circumference reduction and cellulite are available, but most procedures offer suboptimal clinical effect and/or delayed therapeutic outcome. Objective To determine the safety and efficacy of the TriPollar radiofrequency device for cellulite treatment and circumference reduction. METHODS Thirty-nine females with cellulite received eight weekly TriPo...

متن کامل

Non-Surgical Body Contouring: Introduction of a New Non-Invasive Device for Long-Term Localized Fat Reduction and Cellulite Improvement Using Controlled, Suction Coupled, Radiofrequency Heating and High Voltage Ultra-Short Electrical Pulses

Materials and methods: 24 female and 1 male patients were enrolled in the study. The age range of the patients was 28-62 years old and an average BMI was 26. All patients underwent focal shape correction, without anticipating any weight reduction and 14/24 patients also had posterior or anterior grade 2 or 3 thigh cellulite treated. The patients underwent a 6-treatment protocol where they were ...

متن کامل

Painless, safe, and efficacious noninvasive skin tightening, body contouring, and cellulite reduction using multisource 3DEEP radiofrequency.

In the last decade, Radiofrequency (RF) energy has proven to be safe and highly efficacious for face and neck skin tightening, body contouring, and cellulite reduction. In contrast to first-generation Monopolar/Bipolar and "X -Polar" RF systems which use one RF generator connected to one or more skin electrodes, multisource radiofrequency devices use six independent RF generators allowing effic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cosmetic dermatology

دوره 5 4  شماره 

صفحات  -

تاریخ انتشار 2006