Detection of blue under chromatic adaptation: The effects of stimulus size and eccentricity
نویسندگان
چکیده
We measured thresholds for the perception of blue under chromatic adaptation to white, green, yellow or red at the eccentricities of 0-70 deg in the temporal visual field of four subjects. We used a series of stimulus sizes at each eccentricity, without a prior assumption of any peripheral size-scaling factor. The CIE 1976 UCS (u',v') chromaticity coordinates corresponding to blue perception were subtracted from the chromaticity coordinates of the adaptation field in order to obtain the threshold differences (du',dv') in chromaticity coordinates. Spatial scaling factors for the perception of blue were obtained by non-linear regression (E2 + 5 deg) refers to the eccentricity at which stimulus diameter had to be doubled in order to maintain performance found at the eccentricity of 2.5 deg. E2 for the perception of blue tint varied from 1.2 to 36 deg depending on the state of chromatic adaptation and subject. For the perception of blue tint in yellow three subjects and for the perception of blue tint in red one subject had no spatial scaling factor that would make performance independent of eccentricity. Thus, spatial scaling does not always work.
منابع مشابه
Mechanisms mediating visual detection in static perimetry.
PURPOSE The usual stimuli in static perimetry are white-light luminance increments. However, the specific visual detection mechanisms involved in perimetry are unknown because all classes of neural mechanisms are sensitive to spectrally broadband stimuli. The objective of this study was to determine the relative sensitivities of nonopponent and opponent detecting mechanisms under standard perim...
متن کاملEffect of foveal tritanopia on reaction times to chromatic stimuli.
To investigate the effect of foveal inhomogeneities on sensitivity to chromatic stimuli, we measured simple reaction times (RTs) and detection thresholds to temporally and spatially blurred isoluminant stimuli at retinal eccentricities from 0 deg to 8 deg. Three color-normal subjects participated. Contrast gain was derived from the slope of the RT versus contrast function. With a Gaussian spati...
متن کاملComparison of the Eccentricity Faults Effects on the Performance of several Toroidal Wounded Axial Flux Permanent Magnet Motors
Eccentricity fault is one the most common fault types of disk-type permanent magnet machines, which could lead to devastating effects. Unfortunately, most of the previous works have studied this fault and its detection techniques for slotted structure with common winding. Therefore, in this paper, the effects of eccentricity faults on the performance of single-sided slotted, single-sided slotle...
متن کاملA ratio principle for a red/green and a yellow/blue channel?
There is strong empirical evidence that, under adaptation to another achromatic color stimulus, the lightness of an achromatic color stimulus depends on the ratio of the luminances of the two stimuli. In the present study, the suitability of this ratio principle is tested for two chromatic postreceptoral opponent channels. A Hering red/green channel and a non-Hering yellow/blue channel are spec...
متن کاملChromatic temporal integration and retinal eccentricity: Psychophysics, neurometric analysis and cortical pooling
Psychophysical chromatic sensitivity deteriorates in peripheral retina, even after appropriate size scaling of targets. This decrease is more marked for stimuli targeted at the long- (L) to middle-wavelength (M) cone opponent system than for stimuli targeted at short-wavelength (S) pathways. Foveal chromatic mechanisms integrate over several hundred milliseconds for pulse detection. If the time...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vision Research
دوره 35 شماره
صفحات -
تاریخ انتشار 1995