Comparison of in vivo and simulator-retrieved metal-on-metal cervical disc replacements

نویسندگان

  • Steven M. Kurtz
  • Lauren Ciccarelli
  • Megan L. Harper
  • Ryan Siskey
  • Jacob Shorez
  • Frank W. Chan
چکیده

BACKGROUND Cervical disc arthroplasty is regarded as a promising treatment for myelopathy and radiculopathy as an alternative to cervical spine fusion. On the basis of 2-year clinical data for the PRESTIGE(®) Cervical Disc (Medtronic, Memphis, Tennessee), the Food and Drug Administration recommended conditional approval in September 2006 and final approval in July 2007; however, relatively little is known about its wear and damage modes in vivo. The main objective was to analyze the tribological findings of the PRESTIGE(®) Cervical Disc. This study characterized the in vivo wear patterns of retrieved cervical discs and tested the hypothesis that the total disc replacements exhibited similar surface morphology and wear patterns in vitro as in vivo. METHODS Ten explanted total disc replacements (PRESTIGE(®), PRESTIGE(®) I, and PRESTIGE(®) II) from 10 patients retrieved after a mean of 1.8 years (range, 0.3-4.1 years) were analyzed. Wear testing included coupled lateral bending ( ±4.7°) and axial rotation ( ±3.8°) with a 49 N axial load for 5 million cycles followed by 10 million cycles of flexion-extension ( ±9.7°) with 148 N. Implant surfaces were characterized by the use of white-light interferometry, scanning electron microscopy, and energy dispersive spectroscopy. RESULTS The explants generally exhibited a slightly discolored, elliptic wear region of varying dimension centered in the bearing center, with the long axis oriented in the medial-lateral direction. Abrasive wear was the dominant in vivo wear mechanism, with microscopic scratches generally oriented in the medial-lateral direction. Wear testing resulted in severe abrasive wear in a curvilinear fashion oriented primarily in the medial-lateral direction. All retrievals showed evidence of an abrasive wear mechanism. CONCLUSIONS This study documented important similarity between the wear mechanisms of components tested in vitro and explanted PRESTIGE(®) Cervical Discs; however, the severity of wear was much greater during the in vitro test compared with the retrievals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wear simulation of a polyethylene-on-metal cervical total disc replacement under different concentrations of bovine serum lubricant.

Metal-on-polyethylene total disc replacements have been an alternative to spinal fusion in the lumbar spine under certain indications for more than a decade. Recently, cervical total disc replacement has also become an alternative to cervical fusion. Knowledge acquired from years of in vitro simulator studies on other joint replacements has highlighted the risks associated with premature wear d...

متن کامل

Cervical Disc Prosthesis Polyethylene Wear Following The ISO Cervical Test

Introduction: Cervical total disc replacement (TDR) procedures are an option for treatment of cervical spinal disc degeneration. The goal of TDR replacement is to replace the painful and degenerated TDR with a new bearing unit to enable pain free motion. A young and active patient population demands a proven durable replacement bearing surface to accomplish this goal. The wear of that surface m...

متن کامل

The effect of metal ions in solution on bacterial growth compared with wear particles from hip replacements.

The biological significance of cobalt-chromium wear particles from metal-on-metal hip replacements may be different to the effects of the constituent metal ions in solution. Bacteria may be able to discriminate between particulate and ionic forms of these metals because of a transmembrane nickel/cobalt-permease. It is not known whether wear particles are bacteriocidal. We compared the doubling ...

متن کامل

Are PEEK-on-Ceramic Bearings an Option for Total Disc Arthroplasty? An In Vitro Tribology Study

BACKGROUND Most contemporary total disc replacements (TDRs) use conventional orthopaedic bearing couples such as ultrahigh-molecular-weight polyethylene (polyethylene) and cobalt-chromium (CoCr). Cervical total disc replacements incorporating polyetheretherketone (PEEK) bearings (specifically PEEK-on-PEEK bearings) have been previously investigated, but little is known about PEEK-on-ceramic bea...

متن کامل

Assessing the material loss of the modular taper interface in retrieved metal on metal hip replacements

Measuring the amount of material loss in the case of revised hip replacements is considered to be a prerequisite of understanding and assessing the true in vivo performance of the implant. This paper outlines a method developed by the authors for quantifying taper material loss as well as more general taper interface parameters. Previous studies have mostly relied on visual inspection to assess...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2012