Screening for abnormal levels of hyperopia in children: a non-cycloplegic method with a hand held refractor.
نویسندگان
چکیده
AIMS High hyperopia constitutes the majority of refractive errors in large scale visual screening at preschool ages. The authors aimed to assess the validity of the Retinomax hand held refractor to detect high hyperopia in a refractive screening performed without cycloplegia and carried out on children aged 9-36 months. They considered +1.5 D of manifest hyperopia to be the threshold value and abnormal absolute hyperopia to be above +3.5 D. METHODS Of the 897 children screened without cycloplegia, 220 were refracted with cycloplegia. The validity of several thresholds of manifest hyperopia was estimated by receiver operating characteristic (ROC) curves using cycloplegic measures as a reference. The reproducibility of Retinomax measurements was assessed. Normal and quick mode measurements were compared using the Wilcoxon test. RESULTS The manifest threshold of +1.5 D offered the best combination of sensitivity (70.2%), specificity (94.6%), positive predictive value (78.6%), and negative predictive value (91.9%) to disclose abnormal absolute hyperopia. A good agreement was obtained between the various measurements using Retinomax on the same subject. In the results of this survey, there is no evidence that accommodation is minimised in the normal mode of measurement compared with the quick mode. CONCLUSION The Retinomax hand held infrared autorefractor is a suitable instrument to diagnose abnormal hyperopia (manifest hyperopia > +1.5 D) in noncycloplegic refractive screening at preschool ages. It is suggested as the quick mode of measurement as it is more feasible in children (success rate 98.5%).
منابع مشابه
Screening for refractive errors in children: accuracy of the hand held refractor Retinomax to screen for astigmatism.
AIMS To assess the reliability of the hand held automated refractor Retinomax in measuring astigmatism in non-cycloplegic conditions. To assess the accuracy of Retinomax in diagnosing abnormal astigmatism in non-cycloplegic refractive screening of children between 9 and 36 months. METHODS Among 1205 children undergoing a non-cycloplegic refractive screening with Retinomax, 299 (25%) had repea...
متن کاملAccuracy of PlusOptix A09 distance refraction in pediatric myopia and hyperopia
BACKGROUND The PlusOptix photoscreeners (PlusOptix GmbH, Nuremberg, Germany) is used in many vision screening programs. The purpose of the present study was to further explore the accuracy of the PlusOptix A09 photoscreener in children with ametropia (myopia or hyperopia). METHODS A total of 70 eyes (35 children) were prospectively included. Before administration with the cycloplegia treatmen...
متن کاملNon-cycloplegic screening for amblyopia via refractive findings with the Nikon Retinomax hand held autorefractor in 3 year old kindergarten children.
AIMS To assess non-cycloplegic screening for amblyopia with the hand held Nikon Retinomax autorefractor in 3 year old kindergarten children. METHODS 427 three year old children were examined in kindergarten with the Retinomax without cycloplegia. A gold standard was established in all children by two orthoptic examinations in kindergarten. If there were missing, abnormal, or inconsistent find...
متن کاملPre- and Postcycloplegic Refractions in Children and Adolescents
PURPOSE To determine the difference between cycloplegic and non-cycloplegic refractive error and its associated factors in Chinese children and adolescents with a high prevalence of myopia. METHODS A school-based study including 1565 students aged 6 to 21 years was conducted in 2013 in Ejina, Inner Mongolia, China. Comprehensive eye examinations were performed. Pre-and postcycloplegic refract...
متن کاملROC Analysis to Improve Sensitivity and Specificity of the PlusoptiX Photoscreener
The current issue of JOVR includes an article entitled “Is Noncycloplegic Photorefraction Applicable for Screening Refractive Amblyopia risk Factors?”.1 This is a well-constructed study comparing noncycloplegic photorefraction uti l izing the plusoptiX SO4 screener to cycloplegic autorefraction (or cycloplegic retinoscopy in those few children in whom cycloplegic autorefraction could not be per...