Large-plate method for the assay of neomycin in serum.

نویسنده

  • A A Van Soestbergen
چکیده

A large-plate method employing radial diffusion from small paper discs for assaying serum levels of neomycin is described. More than 120 discs placed on a loading plate and loaded with 20 muliters of sample could all be brought into contact with the agar plate at one time. The requirement for elaborate statistical design to compensate for time-dependent bias was thus eliminated. The dose-response curve was linear for a range of at least 0.5 to 2.5 mug/ml. The experimental limits for the actual zone width (distance from the edge of the paper disc to the outer edge of the inhibition zone) for 120 repetitions of the assay of neomycin in one and the same serum, carried out simultaneously on one large plate, were about +/- 6% (95% confidence interval). The 95% confidence interval for the distribution of difference between duplicate zones obtained for the assay of neomycin in 34 different sera, also carried out on one plate, was about +/- 10%. The dose-response lines for a standard and for three unknown sera, when carried out together on one plate, were parallel within the variability (+/- SD one) of the zone width. The large-plate method is considered to be more efficient than the use of the smaller petri dishes. The method is suitable for the assay of penicillin in serum and can most probably be used for the assay of a wide variety of substances for which radial diffusion from paper discs into agar is feasible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ایجاد یک روش نوین آزمایشگاهی الایزا توبی (ToBi Assay) برای تعیین پوتنسی واکسن بومی توکسوییدی کزاز درایران

Background: One of the major uses of large number of laboratory animals in manufacturing the vaccines is the quality control testing of vaccines, particularly potency testing of vaccines containing the tetanus toxoids by either lethal challenge or serum neutralization tests. Recently, because of various difficulties to obtain quality laboratory animals and in adequate environmental conditions, ...

متن کامل

Non-linear Static Modeling of Moderately Thick Functionally Graded Plate Using Dynamic Relaxation Method

In this paper, nonlinear static analysis of moderately thick plate made of functionally graded materials subjected to mechanical transverse loading is carried out using dynamic relaxation method. Mindlin first order shear deformation theory is employed to consider thick plate. Discretized equations are extracted for geometrically nonlinear behavior analysis.Loading Conditions and boundary condi...

متن کامل

New Method for Large Deflection Analysis of an Elliptic Plate Weakened by an Eccentric Circular Hole

The bending analysis of moderately thick elliptic plates weakened by an eccentric circular hole has been investigated in this article. The nonlinear governing equations have been presented by considering the von-Karman assumptions and the first-order shear deformation theory in cylindrical coordinates system. Semi-analytical polynomial method (SAPM) which had been presented by the author before...

متن کامل

Effects of Geometric Nonlinearity on Stress Analysis in Large Amplitude Vibration of Moderately Thick Annular Functionally Graded Plate

This paper deals with the nonlinear free vibration of thick annular functionally graded material plates. The thickness is assumed to be constant. Material properties are assumed to be graded in the thickness direction according to a simple power law distribution in terms of the volume fractions of the constituents. The formulations are based on the first-order shear deformation plate theory and...

متن کامل

Immunodiagnosis of Haemonchus contortus infection in sheep by indirect enzyme linked immunosorbent assay (ELISA)

Indirect plate enzyme-linked immunosorbent assay was standardized and evaluated for its effectivenessin immunodiagnosis of haemonchosis in experimental and clinical cases in sheep by using somatic wholeadult antigen of H. contortus. Plate ELISA was standardized using 5 μg/well antigen concentration with1:100 and 1:1000 of sera and conjugate dilution. Indirect plate ELISA was able to demonstrate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied microbiology

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 1969