Influence of microbubble surface charge on capillary transit and myocardial contrast enhancement.

نویسندگان

  • Nicholas G Fisher
  • Jonathan P Christiansen
  • Alexander Klibanov
  • Ronald P Taylor
  • Sanjiv Kaul
  • Jonathan R Lindner
چکیده

OBJECTIVE The goal of the study was to determine whether microbubble charge influences the microvascular retention of microbubble contrast agents. BACKGROUND Interactions between serum proteins and lipid membranes are greater with anionic compared with neutral membranes. These interactions may influence the microvascular behavior of anionic lipid microbubbles. METHODS Intravital microscopy of the cremaster muscle was performed in six wild-type mice and three C3-deficient mice during intravenous injection of lipid-shelled microbubbles with either a neutral or a negative charge. Both agents were prepared with and without a protective surface layer of polyethyleneglycol (PEG). Complement attachment to microbubbles was assessed by flow cytometry with flourescein isothiocyanate-conjugated anti-C3b monoclonal antibody. Myocardial contrast echocardiography was performed in six dogs to assess pulmonary and myocardial retention of microbubbles. RESULTS Size-independent capillary retention of microbubbles, occurring for a few seconds to >10 min, was frequently observed with anionic, but rarely with neutral, microbubbles (4.3 +/- 0.3 vs. 0.4 +/- 0.1 mm(-3), p < 0.01). Anionic microbubble retention was reduced by 70% by surface PEG and was also markedly reduced in C3-deficient mice (1.4 +/- 0.1 mm(-3), p < 0.05 vs. wild-type). Flow cytometry demonstrated complement attachment to only anionic microbubbles. Contrast echocardiography indicated both pulmonary and myocardial retention of only anionic microbubbles, the latter evidenced by persistent opacification >10 min after bolus intravenous injection. CONCLUSIONS Lipid microbubbles with a net negative charge can be retained within capillaries via complement-mediated attachment to endothelium. This property may be useful for the development of ultrasound contrast agents that can be imaged late after venous injection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling and investigating the effect of ultrasound waves pressure on the microbubble oscillation dynamics in microvessels containing an incompressible fluid (Research Article)

Understanding the dynamics of microbubble oscillation in an elastic microvessel is important for the safe and effective applications of ultrasound contrast agents in imaging and therapy. Numerical simulations based on 2D finite element model are performed to investigate the effect of acoustic parameters such as pressure and frequency on the dynamic interaction of the fluid-blood-vessel system. ...

متن کامل

In vivo myocardial kinetics of air-filled albumin microbubbles during myocardial contrast echocardiography. Comparison with radiolabeled red blood cells.

Myocardial contrast echocardiography (MCE) is a new technique for assessing myocardial perfusion that uses intracoronary injections of microbubbles of air. Because these microbubbles have a mean diameter of 4.3 +/- 0.3 microns and an intravascular rheology similar to that of red blood cells (RBCs), we hypothesized that their mean myocardial transit rates recorded on echocardiography would provi...

متن کامل

Capillary Effects on Surface Enhancement in a Non-Homogeneous Fibrous Porous Medium

The evaluation of a free fluid surface in a porous medium has several mathematical applications that are important in industries using molds, particularly in the fluid injection process. The vacuum-assisted resin transfer molding (VARTM) process is a promising technology in the primary composite industry. An accurate computational simulation of the VARTM process would be a cost-effective tool i...

متن کامل

Pulse Inversion Imaging of Liver with Microbubble Contrast: Improved Characterization of Tumoral Vasculature in Focal Hepatic Lesions

The challenge presented to ultrasound imaging technology by the advent of microbubble contrast agents is to create a method that detects the echoes from bubbles in preference to the echoes from tissue. Recent progress in ultrasonography is represented by the development of harmonic and pulse inversion imaging (Fig. 1, 2). Pulse inversion imaging is a newly developed one, which uses the full ban...

متن کامل

Albumin microbubble persistence during myocardial contrast echocardiography is associated with microvascular endothelial glycocalyx damage.

BACKGROUND We hypothesized that the persistence of albumin microbubbles within the myocardium during crystalloid cardioplegia (CP) infusion and ischemia-reperfusion (I-R) occurs because of endothelial injury. METHODS AND RESULTS The myocardial transit rate of albumin microbubbles was measured in 18 dogs perfused with different CP solutions and in 12 dogs undergoing I-R. Electron microscopy wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 40 4  شماره 

صفحات  -

تاریخ انتشار 2002