Pool Boiling Heat Transfer Characteristics of Nanofluids by Sung Joong
نویسنده
چکیده
Nanofluids are engineered colloidal suspensions of nanoparticles in water, and exhibit a very significant enhancement (up to 200%) of the boiling Critical Heat Flux (CHF) at modest nanoparticle concentrations (50.1% by volume). Since CHF is the upper limit of nucleate boiling, such enhancement offers the potential for major performance improvement in many practical applications that use nucleate boiling as their prevalent heat transfer mode. The nuclear applications considered are main reactor coolant for PWR, coolant for the Emergency Core Cooling System (ECCS) of both PWR and BWR, and coolant for in-vessel retention of the molten core during severe accidents in high-powerdensity LWR. To implement such applications it is necessary to understand the fundamental boiling heat transfer characteristics of nanofluids. The nanofluids considered in this study are dilute dispersions of alumina, zirconia, and silica nanoparticles in water. Several key parameters affecting heat transfer (i.e., boiling point, viscosity, thermal conductivity, and surface tension) were measured and, consistently with other nanofluid studies, were found to be similar to those of pure water. However, pool boiling experiments showed significant enhancements of CHF in the nanofluids. Scanning Electron Microscope (SEM) and Energy Dispersive Spectrometry (EDS) analyses revealed that buildup of a porous layer of nanoparticles on the heater surface occurred during nucleate boiling. This layer significantly improves the surface wettability, as shown by measured changes in the static contact angle on the nanofluid-boiled surfaces compared with the pure-water-boiled surfaces. It is hypothesized that surface wettability improvement may be responsible for the CHF enhancement.
منابع مشابه
FLOW VISUALIZATION AND STUDY OF CRITICAL HEAT FLUX ENHANCEMENT IN POOL BOILING WITH Al2O3-WATER NANOFLUIDS
Pool boiling heat transfer characteristics of Al2O3 -water nanofluids is studied experimentally using a NiCr test wire of 36 standard wire guage diameter. The experimental work mainly concentrated on (1) change of critical heat flux with different volume concentrations of nanofluid and (2) flow visualization of pool boiling using a fixed concentration of nanofluid at different heat flux values....
متن کاملPool boiling of water-Al2O3 and water-Cu nanofluids on horizontal smooth tubes
Experimental investigation of heat transfer during pool boiling of two nanofluids, i.e., water-Al2O3 and water-Cu has been carried out. Nanoparticles were tested at the concentration of 0.01%, 0.1%, and 1% by weight. The horizontal smooth copper and stainless steel tubes having 10 mm OD and 0.6 mm wall thickness formed test heater. The experiments have been performed to establish the influence ...
متن کاملA review on boiling heat transfer enhancement with nanofluids
There has been increasing interest of late in nanofluid boiling and its use in heat transfer enhancement. This article covers recent advances in the last decade by researchers in both pool boiling and convective boiling applications, with nanofluids as the working fluid. The available data in the literature is reviewed in terms of enhancements, and degradations in the nucleate boiling heat tran...
متن کاملDetermination of Pool Boiling Critical Heat Flux Enhancement in Nanofluids
Nanofluids are engineered colloids composed of nano-size particles dispersed in common fluids such as water or refrigerants. Using an electrically controlled wire heater, pool boiling Critical Heat Flux (CHF) of Alumina and Silica water-based nanofluids of concentration less than or equal to 0.1 percent by volume were measured. Silica nanofluids showed CHF enhancement up to 68% and there seems ...
متن کاملPool Boiling Heat Transfer in Water/Amines Solutions
In this investigation, nucleate boiling heat transfer coefficients were experimentally measured during pool boiling of mixtures, consisting of water/monoethanolamine and water/diethanolamine on a horizontal heating rod, under atmospheric pressure. The experiment was carried out below 205 kW.m-2 heat flux, over a wide range of concentrations. These experiments include, measurement of pool boilin...
متن کامل